Calculation Using Distance-Volume Table – Allows setting a linearization table based on distance to
volume conversion (to be done the same as above). In this case, the two editable columns are Distance
[m] and Volume [m^3], as shown in
Figure 7-65. Distance-Volume Linearization Table
Calculation Using Level-Mass Table – Conversion of the calculated average level directly into mass.
Figure 7-66. Output Type Mass by Level-Mass Table
Select Edit Table... to edit the Level-Mass Linearization table.
If the Level to Mass option is selected, the 2 editable columns are Level [m] and Mass [ton], as shown in
Figure