Emerson IC695PNS001-BHBF1 2 Important Product Information
Emerson IC695PNS001-BHBF1 2 Important Product Information

Emerson IC695PNS001-BHBF1 2 Important Product Information

Advertisement

Quick Links

PACSystems™ RX3i PROFINET Scanner &
Advanced PROFINET Scanner
Firmware Version 3.41
RX3i PROFINET Scanner
IC695PNS001-BHBF
RX3i Advanced PROFINET Scanner
IC695PNS101-AFAD
1
Includes conformal coat and low temperature module variants, if available.
2
The last two characters of the catalog number suffix may not increment with every firmware release beginning with IC695PNS001-BDBE &
IC695PNS101-ACAC Release 3.20.
1 2
1 2
IMPORTANT PRODUCT INFORMATION
GFK-2738AE
Jan 2024

Advertisement

Table of Contents
loading

Summary of Contents for Emerson IC695PNS001-BHBF1 2

  • Page 1 IMPORTANT PRODUCT INFORMATION GFK-2738AE Jan 2024 PACSystems™ RX3i PROFINET Scanner & Advanced PROFINET Scanner Firmware Version 3.41 RX3i PROFINET Scanner IC695PNS001-BHBF RX3i Advanced PROFINET Scanner IC695PNS101-AFAD Includes conformal coat and low temperature module variants, if available. The last two characters of the catalog number suffix may not increment with every firmware release beginning with IC695PNS001-BDBE & IC695PNS101-ACAC Release 3.20.
  • Page 2 Changes, modifications, and/or improvements to equipment and specifications are made periodically and these changes may or may not be reflected herein. It is understood that Emerson may make changes, modifications, or improvements to the equipment referenced herein or to the document itself at any time. This document is intended for trained personnel familiar with the Emerson products referenced herein.
  • Page 3 GFK-2738AE Jan 2024 Overview The PACSystems™ IC695PNS001 RX3i PROFINET Scanner and IC695PNS101 RX3i Advanced PROFINET Scanner modules connect a remote universal RX3i I/O rack of RX3i modules to a PROFINET I/O Controller. The PROFINET Scanner scans the modules in its rack, retrieving input data and providing output data, and exchanges that data on the PROFINET I/O LAN at the configured production rate.
  • Page 4: Specifications

    GFK-2738AE Jan 2024 Current Release Information PACSystems RX3i PROFINET Scanner (PNS), IC695PNS001, and Advanced PROFINET Scanner IC659PNS101 Release 3.41 resolves issues found in Section Problems Resolved by this Revision. Firmware Version Numbers Firmware Component Version Number PNS001-Bxxx / PNS101-Axxx Primary Firmware Release 3.41 Build ENB6 PNS001-Bxxx / PNS101-Axxx Boot Firmware Release 1.08 Build EKJU...
  • Page 5 GFK-2738AE Jan 2024 Specifications Descriptions PNS001-Bxxx or later: PNS001-Axxx: PNS101-Axxx or later: • 3.3 Vdc • 3.3 Vdc • 1.2 A with no SFP devices installed • 0.6 A with no SFP devices installed • 1.9 A maximum (two SFP devices •...
  • Page 6: Profinet Scanner Status And Control Data

    GFK-2738AE Jan 2024 PROFINET Scanner Status and Control Data The RX3i PROFINET Scanner provides 32 bits of input status data and receives 32 bits of output control data. The application program in the I/O Controller system can monitor the input status bits for the PNS module. The output control bits are reserved for future use and have no function at this time.
  • Page 7: Leds On The Profinet Scanner Module

    GFK-2738AE Jan 2024 LEDs on the PROFINET Scanner Module Power-Up LED Patterns At power-up, the LEDs show the patterns described in the following table. The LEDs also blink diagnostic patterns for certain operating errors and module identification. Step LED/ Blink pattern Description Figure 1: PNS101 All LEDs off...
  • Page 8 GFK-2738AE Jan 2024 Normal Operation of Individual LEDs The PNS’s LEDs can operate in tandem to indicate a fatal error, module location/identification, microprocessor over-temperature, and update conditions. For details on these blink patterns, refer to PACSystems RX3i PROFINET Scanner Manual, GFK-2737. OK LED The OK LED indicates whether the module can perform a normal operation.
  • Page 9 GFK-2738AE Jan 2024 Port LEDs The PROFINET Scanner has four LEDs that indicate link speed, link connection, and link activity corresponding to the four possible external Ethernet ports. Port Number LED Color Description Red, on Port 3 and 4 only: Error such as incompatible SFP. No Port error.
  • Page 10 As the consignee, it is your responsibility to register a claim with the carrier for damage incurred during shipment. However, Emerson will fully cooperate with you, should such action be necessary. After unpacking the RX3i equipment, record all serial numbers. Serial numbers are required if you should need to contact Customer Care during the warranty period.
  • Page 11 GFK-2738AE Jan 2024 Installing the PNS in an RX3i Backplane 1. The Scanner can be installed in slot 1 or 2 of a 7, 12, Figure 2: Installing the PNS Module into a or 16-slot RX3i Universal Backplane, or slot 6 of a 7- Backplane slot RX3i Universal Backplane.
  • Page 12 GFK-2738AE Jan 2024 Connecting the PNS to the PROFINET network and a 10BaseT, 100BaseTX, or 1000BaseT IEEE 802.3 network for general Ethernet communications Each port on an RX3i PNS module (Figure 3) operates independently, so devices that operate at different speeds and/or duplex modes may be attached to the ports.
  • Page 13: Supported Modules, Power Supplies, And Backplanes

    GFK-2738AE Jan 2024 2. Assigning an I/O Device Name to the PNS Before attempting to connect to or configure the RX3i PNS, the I/O Device Name must be set with a Discovery and Configuration Protocol (DCP) tool, such as the PAC Machine Edition Discovery Tool. 3.
  • Page 14 GFK-2738AE Jan 2024 Catalog Number Module Description Distinguishing Classes IC694MDL250 16 Circuit Input 120 Vac Isolated none IC694MDL260 32 Circuit Input 120 Vac none IC694MDL632 8 Circuit Input 125 Vdc Positive / Negative Logic 8 in IC694MDL634 8 Circuit Input 24 Vdc Positive / Negative Logic 8 in IC694MDL635 16 Circuit Input 125 Vdc Positive / Negative Logic...
  • Page 15 GFK-2738AE Jan 2024 Catalog Number Module Description Distinguishing Classes IC694MDL732 8 Circuit Output 12/24 Vdc 0.5A Positive 8 out IC694MDL734 6 Circuit Output 125 Vdc 1A Positive/Negative 8 out IC694MDL740 16 Circuit Output 12/24 Vdc 0.5A Positive 16 out IC694MDL741 16 Circuit Output 12/24 Vdc 1A Negative 16 out IC694MDL742...
  • Page 16 GFK-2738AE Jan 2024 Catalog Number Module Description Distinguishing Classes IC695ALG708 8 Point Analog Current / Voltage Output none IC695ALG728 8 Point Analog Current / Voltage Output (HART Support) none IC695ALG808 8 Point Isolated Analog Current / Voltage Output none Analog Mixed Modules IC693ALG442 4 Input / 2 Output, Current / Voltage ALG IN 4, ALG OUT 2...
  • Page 17: Release History

    Mar 2020 IC695PNS101-ACAC Resolves issues described in the section entitled Problems Resolved by this Revision Added support for the IC694MDL730 & IC694MDR390, rebranded the PNS001/PNS101 and GSDML to Emerson, and applied patches IC695PNS001-BDBE 3.20 Oct 2019 for VxWorks URGENT/11 vulnerabilities.
  • Page 18: Field Upgrade

    GFK-2738AE Jan 2024 Firmware Version Date Comments Revision Firmware is not compatible with previous hardware revisions (- AXXX). IC695PNS001-BABA is Achilles Level 1 Certified. Added support for the Remote Get HART Device Information COMMREQ. Information from a HART device connected to an RX3i IC695PNS001-ABAK 2.41 Jun 2016...
  • Page 19 GFK-2738AE Jan 2024 Problems Resolved by this Revision Subject Defect Description IC695PNSx01 DE10626 The IC695PNS001-Bxxx or IC695PNS101 could incorrectly indicate an Overtemperature resets overtemperature condition and reset even when the operating temperature is within normal ranges. Functional Compatibility The following CPU firmware, programming software, and backplane hardware versions are required to use the features introduced in the most recent PNS release: Description Subject...
  • Page 20 GSDML-V2.3-IntelligentPlatformsLLC-RX3iPNS- IC694MDL655 SoE 3.25 20191010.xml PNS101 Release 3.25 GSDML IC694MDL730, PNS001-Bxxx Release GSDML-V2.3-IntelligentPlatformsLLC-RX3iPNS- Version IC694MDR390, 3.20 20190820.xml Emerson rebranding PNS101 Release 3.20 PNS101 PNS101 Release 3.10 GSDML-V2.3-GEIP-RX3iPNS-20180724.xml PNS001-Bxxx Release IC695HSC304 3.10 GSDML-V2.3-GEIP-RX3iPNS-20180724.xml PNS101 Release 3.10 PNS001-Bxxx Release PNS001-Bxxx GSDML-V2.3-GEIP-RX3iPNS-20170109.xml 3.00...
  • Page 21: Operational Notes

    GFK-2738AE Jan 2024 Description Subject Minimum PNS Minimum Version Required Feature Version Required The following minimum backplane hardware revision must be used: IC695CHS012-BAMP IC695CHS016-BAMP IC695CHS012CA-BAMP IC695CHS016CA-BAMP IC695CHS012-CA (or later) IC695CHS016-CA (or later) RX3i IC695CHS012CA-CA (or later) IC695CHS016CA-CA (or later) backplane hardware IC695CHS007-AA (or later) When installing, operating, or maintaining the PNS, personnel must ensure any electrostatic charge is...
  • Page 22 GFK-2738AE Jan 2024 Subject Description For analog input and output modules that support alarms, the PNS limits alarm values to the range specified by the High and Low Engineering Unit values. If the High and Low Scale A/D Unit values are not the full range of the analog signal, runtime values reported in Engineering Units may exceed the High or Low Engineering range.
  • Page 23 GFK-2738AE Jan 2024 Subject Description To ensure correct MRP ring-break detection, it is important to connect the correct Ethernet ports of the RX3i PNS to the MRP ring. The ports connected to the ring must be the same ports configured as MRP Ring Ports. Failure to connect the configured ports will prevent the PNS from correctly participating in the MRP ring, Connecting Ethernet Ports Not may inhibit ring-break detection, and may result in losses of IO Devices upon...
  • Page 24: Product Documentation

    Jan 2024 Product Documentation For additional information, please refer to the manuals listed below. Manuals can be downloaded from the support website, http://www.emerson.com/industrial-automation-conrtrols/support PACSystems RX3i, and RSTi-EP CPU Reference Manual GFK-2222 PACSystems RX3i & RSTi-EP PROFINET I/O Controller User Manual...
  • Page 25 Note: If the product is purchased through an Authorized Channel Partner, please contact the seller directly for any support. Emerson reserves the right to modify or improve the designs or specifications of the products mentioned in this manual at any time without notice. Emerson does not assume responsibility for the selection, use or maintenance of any product.

This manual is also suitable for:

Pacsystems rx3iIc695pns101-afad1 2

Table of Contents