Table 8-13. HP24BO, BS, RO, RS, TO, TS, HK24BO, RO, TO, HM24RO, TO Load Operation Modes
Models: HP24BO, BS, RO, RS, TO, TS, HK24BO, RO, TO, HM24RO, TO
Electronic Control:
Defrost Style:
Cabinet Lighting:
Evaporator Fan:
LOAD
Compressor
Condenser Fan
Evaporator Fan

Table 8-14. HP24WO, WS, HK24WO Load Operation Modes

Models: HP24WO, WS, HK24WO
Electronic Control:
Defrost Style:
Cabinet Lighting:
Evaporator Fan:
LOAD
Compressor
Condenser Fan
Evaporator Fan

Table 8-15. HP24FO, FS, HK24FO Load Operation Modes

Models: HP24FO, FS, HK24FO
Electronic Control:
Defrost Style:
Cabinet Lighting:
Evaporator Fan:
LOAD
Compressor
Condenser Fan
Evaporator Fan
Hot Gas Solenoid Valve
*Defrost is elapsed time initiated and terminated (See controller programs)
**Fan motors are off/delayed after defrost (see controller programs)
Return to
Table of Contents
Dixell (XR60CX)
Programmed Defrost (12 hours--15 minutes)
Lights are controlled through a manual on/off switch as well as
through the door switch.
Is controlled by the door switch during Cooling Mode
COOLING MODE
Energized
Energized
Energized
Dixell (XR60CX)
Off Cycle Defrost
Lights are controlled through a manual on/off switch as well as
through the door switch.
Is controlled by the door switch during Cooling Mode
COOLING MODE
Energized
Energized
Energized
Dixell (XR60CX)
Hot Gas Defrost
Lights are controlled through a manual on/off switch as well as
through the door switch.
Is controlled by the door switch during Cooling Mode
COOLING MODE
Energized
Energized
Energized
De-Energized
Electrical System Repair Instructions
OFF MODE
DEFROST MODE
De-Energized
De-Energized
De-Energized
De-Energized
De-Energized
Energized
OFF MODE
DEFROST MODE
De-Energized
N/A
De-Energized
N/A
Energized
N/A
OFF MODE
DEFROST MODE
De-Energized
Energized
De-Energized
De-Energized
De-Energized
De-Energized
De-Energized
Energized