STEP 4.

The black mullion heater wire with the red female push connector will connect to a red male push on
connector that has a white cap. It is also a black wire.
This male connector can be a little tricky to locate. It should be tucked behind the compressor towards the
front and behind the white DC Inverter mounted to the floor. It might be easier to push this wire to the
rear from the front.
Red Male Push on Connector
STEP 5.
Remove the plastic caps and connect the white wires to the white wire and the black wire to the black.
Return to
Table of Contents
Electrical System Repair Instructions
White DC Inverter (front view)