18” shallow-depth series beverage center/48” signature series refrigerator / wine reserve stacked on a 48” signature series freezer / refrigerator drawers (12 pages)
For your own protection, never return Serial Number: _________________________ merchandise for credit without our approval. Purchase Date: _______________________ We thank you for selecting a Perlick product Dealer Name & Address and assure you of our continuing interest in your ______________________________________ satisfaction.
Page 3
To ensure proper performance, the air intake minimum of 24 hours before connecting the (toe kick) must not be blocked. Perlick refrigera- unit. Failure to do so can affect the function tion is front-breathing, and covering the intake and performance of the appliance.
The outlet should 2" performed by a Perlick authorized servicer. be placed in the hatched area dimensioned below. Work done by unqualified individuals could 84"...
For Built-In Applications Opening Dimensions The depth of each Perlick column is 24” (610) to door face (not including the 3/4” overlay). Allow for door panel thickness when planning the finished opening depth. A minimum of 4” (102) finished return is required on all sides of the opening.
Page 6
WHEN BUILDING INTO STRUCTURE OR NEXT TO ADJACENT WALLS REFERENCE THIS DRAWING FOR MINIMUM REQUIRED CLEARANCES TO AVOID INTERFERANCE WHEN OPENING THE DOOR(S). THE ADJACENT STRUCTURE CLEARANCES INDICATED ARE BASED ON A STANDARD PERLICK HANDLE INSTALLED ON THE DOOR OVERLAY. MINIMUM SPACING REQUIRED BETWEEN ADJACENT CABINETS TO AVOID DOOR SWING INTERFERENCE.
Page 7
Wine Column Refrigeration Installation & Operation Manual INSTALLATION CONTINUED MINIMUM SPACING REQUIRED BETWEEN ADJACENT CABINETS TO AVOID DOOR SWING INTERFERENCE CONTINUED. Opening Dimensions (C) 2 Cabinets HANDLE TO HINGE. Refer to (C) Opening diagram (page 8) for finished opening dimensions and outlet locations. (D) 3 Cabinets with Hinges either all left or all right.
Page 8
Wine Column Refrigeration Installation & Operation Manual INSTALLATION CONTINUED MINIMUM SPACING REQUIRED BETWEEN ADJACENT CABINETS TO AVOID DOOR SWING INTERFERENCE CONTINUED. (G) 3 Cabinets with Hinges Right-Left-Left or Left- Right-Right. Refer to (G) Opening diagram (page 9) for finished opening dimensions and outlet locations. FINISHED OPENING DIMENSIONS FOR 2 AND 3 UNIT INSTALLATIONS.
Page 9
Wine Column Refrigeration Installation & Operation Manual INSTALLATION CONTINUED FINISHED OPENING DIMENSIONS FOR 2 AND 3 UNIT INSTALLATIONS CONTINUED. Note: For installations involving more than 3 cabinets, combine opening dimensions for the openings which correspond to the combined Hinge and Handle configurations. Printed in USA...
Wine Column Refrigeration Installation & Operation Manual PLACEMENT & ALIGNMENT CAUTION Once the unit is in position, height adjustment Before moving the unit can be made from the front. Using the hex into position, secure the door closed and driver leveling tool, turn clockwise to raise the protect any finished flooring.
Wine Column Refrigeration Installation & Operation Manual ANTI - TIP BRACKET CAUTION The anti-tip bracket and supporting hardware A l w a y s w e a r s a f e t y is included with your unit. In the case of dual glasses and use other necessary protective installation, each individual unit must be outfitted devices or apparel when installing or working...
Page 12
Wine Column Refrigeration Installation & Operation Manual Anti-Tip Application for Freestanding Applications NOTE: Cabinet must be leveled before securing to wall with anti-tip bracket. Printed in USA...
4 " THIS DOCUMENT / PUBLICATION / SOFTWARE / DRAWING CONTAINS PROPRIETARY INFORMATION WHICH FORM, ELECTRONIC OR MECHANICAL, INCLUDING PHOTOCOPYING, RECORDING, OR USED IN ANY INFORMAT CORPORATION. COPYRIGHT 2015 PERLICK SW C:\Perlick\Engineering\Projects\Refrigeration\1601802\CAD Files\1007917.slddrw 4” Toe Kick Wood Overlay Template Glass Door...
Page 14
Wine Column Refrigeration Installation & Operation Manual INSTALLING DOOR OVERLAY PANELS CONTINUED Custom Overlay Panels A custom door panel and handle hardware must be installed. The thickness of the custom panel can vary. A minimum 5/8” (16) thick panel is required, but the thickness can be increased provided it does not exceed the maximum panel weight of 65 lbs (29).
Page 15
Wine Column Refrigeration Installation & Operation Manual DOOR OVERLAY PANEL ADJUSTMENT Close the door to make adjustments to align panels and reveals. For up-and-down adjustments, turn the height adjustment screws in the top bracket in and out. DOOR Adjust the screws as needed to achieve an even reveal on each side of the door overlay.
Wine Column Refrigeration Installation & Operation Manual DOOR TRIM INSTALLATION Once overlay is adjusted, mount the door trim bracket onto the door adjustment bracket using the provided screws. DOOR TRIM DOOR TRIM DETAIL J SCALE 1 : 6 DOOR TRIM DOOR PANEL FRAME 2 OVERLAY...
Milwaukee, WI 53223 THIS DOCUMENT/PUBLICATION/SOFTWARE/DRAWING CONTAINS PROPRIETARY INFORMATION WHICH IS THE PROPERTY OF THE PERLICK CORPORATION. IT MAY NOT BE REPRODUCED OR TRANSMITTED IN ANY FORM, ELECTRONIC OR MECHANICAL, INCLUDING PHOTOCOPYING, RECORDING, OR USED IN ANYINFORMATION STORAGE, TRANSMISSION, OR RETRIEVAL SYSTEM, WITHOUT WRITTEN PERMISSION FROM THE PERLICK CORPORATION COPYRIGHT 2001 PERLICK CORPORATION.
Wine Column Refrigeration Installation & Operation Manual WINE COLUMN DIGITAL CONTROL OPERATION WINE COLUMN DIGITAL CONTROL OPERATION The following instructions are for the PerlIQ™ digital controller in Perlick column wine reserves (models CC24W and CC24D). Using the Wine Column Control Wake Button...
Page 20
Wine Column Refrigeration Installation & Operation Manual Storing White Wine Cellaring Wine Perlick wine columns are preset with expert- Perlick wine columns are preset with expert- recommended temperature settings for white wine. To recommended temperature settings for cellaring (long- set a zone in dual zone models to this preset, touch the term storage) wine.
Page 21
Sabbath Mode Showroom Mode All Perlick column refrigeration models have Sabbath Select Showroom mode for units that are being used mode capabilities. This allows the user to interact with the solely for display purposes. Showroom mode has the unit without changing the amount of energy it is using.
Three materials or processes can break down stainless steel’s passive layer, allowing corrosion to occur. Perlick’s black metallic surface is finished with powder coat. When properly cared for, powder coating provides a durable, ▪ Mechanical Abrasion This refers to items that will uniform finish that is resistant to scuffing, scratching or staining.
Wine Column Refrigeration Installation & Operation Manual WINE STORAGE Wine Shelving ▪ Prior to making shelf adjustments, clear the shelf of product. Shelf must be empty prior to changing its position. To Install Wine Shelves To Remove Wine Shelves PILASTER PILASTER FIXED SLIDER WITH BRACKET FIXED SLIDER WITH BRACKET...
Page 24
Milwaukee, WI 53223 THIS DOCUMENT/PUBLICATION/SOFTWARE/DRAWING CONTAINS PROPRIETARY INFORMATION WHICH IS THE PROPERTY OF THE PERLICK CORPORATION. IT MAY NOT BE REPRODUCED OR TRANSMITTED IN ANY FORM, ELECTRONIC OR MECHANICAL, INCLUDING PHOTOCOPYING, RECORDING, OR USED IN ANYINFORMATION STORAGE, TRANSMISSION, OR RETRIEVAL SYSTEM, WITHOUT WRITTEN PERMISSION FROM THE PERLICK CORPORATION COPYRIGHT 2001 PERLICK CORPORATION.
Any changes to an carrier’s responsibility. Before giving the carrier Order must be in writing and signed by Perlick a clean receipt at time of delivery, make sure you and Buyer.
Page 26
Perlick’s one year labor warranty provides series back bars and accessory parts is 20%. that Perlick will pay for the cost of any labor to The minimum restocking charge for custom replace any defective part for up to one year series cabinets is 50%.
Need help?
Do you have a question about the CC24W Series and is the answer not in the manual?
Questions and answers