Step - Perlick HA24BB Service Manual

Residential and commercial front venting refrigeration
Hide thumbs Also See for HA24BB:
Table of Contents

Advertisement

Residential Refrigeration
and Front Venting Commercial Refrigeration
Service Manual
Replace Door Handle
Tools required
3/8"

STEP 3.

Remove door gasket. See Section 9.5.
STEP 4.
Remove 16 screws underneath door gasket that
hold door overlay panel to door frame.
STEP 5.
Separate door overlay panel from door frame.
STEP 6.
Door handle can now be removed, by removing
fasteners attaching handle to overlay on top and
bottom.
Return to
Table of Contents
STEP 7.
Reverse these steps to replace door handle,
overlay panel, and gasket.
Lock Troubleshooting
Gain access to back side of the lock by following
directions to remove door handle, Section 9.7.
Note position of door lock cam and reassemble in
the same orientation.
PROBLEM
Lock rotates but doesn't
engage catch
Lock catch interferes with
door
Key will not disengage from
lock
Replacement Parts
CAUSE
Lock misassembled and has
cam in incorrect orientation
Cam is missing
Misalignment of cam and
catch
Catch is bent
Door is out of alignment
Lock is not installed properly
in the door
Key is over-rotated
Page 9-7