Residential Refrigeration
and Front Venting Commercial Refrigeration
Service Manual
Load Operation Modes
Table 8-2. HA24BB, RB, WB Load Operation Modes
Models: HA24BB, RB, WB
Temperature Control:
Defrost Style:
Cabinet Lighting:
Evaporator Fan:
LOAD
Compressor
Condenser Fan
Evaporator Fan
Models: HA24FB
Electronic Control:
Defrost Style:
Cabinet Lighting:
Evaporator Fan:
LOAD
Compressor
Condenser Fan
Evaporator Fan
Hot Gas Solenoid Valve
Models: HB24BS, RS, WS
Temperature Control:
Defrost Style:
Cabinet Lighting:
LOAD
Compressor
Condenser Fan
Evaporator Fan
Return to
Table of Contents
Electro-mechanical
Off cycle defrost
Lights are controlled through a manual on/off switch as well as
through the door switch.
Is controlled by the door switch during Cooling Mode
COOLING MODE
Energized
Energized
Energized
Table 8-3. HA24FB Load Operation Modes
Dixell (XR60CX)
Hot Gas Defrost
Lights are controlled through a manual on/off switch as well as
through the door switch.
Is controlled by the door switch during Cooling Mode
COOLING MODE
Energized
Energized
Energized
De-Energized
*Defrost is elapsed time initiated and terminated (See controller programs)
**Fan motors are off after defrost (see controller programs)
Table 8-4. HB24BS, RS, WS Load Operation Modes
Electro-mechanical
Off cycle defrost
Lights are controlled through a manual on/off switch as well as
through the door switch.
COOLING MODE
Energized
Energized
Energized
Electrical System Repair Instructions
OFF MODE
DEFROST MODE
De-Energized
N/A
De-Energized
N/A
De-Energized
N/A
OFF MODE
DEFROST MODE
De-Energized
Energized
De-Energized
De-Energized
De-Energized
De-Energized
De-Energized
Energized
OFF MODE
DEFROST MODE
De-Energized
N/A
De-Energized
N/A
De-Energized
N/A
Page 8-18