8.6.1 Dixell Controller: Reset Factory Parameter
Settings
Contact Perlick.
8.6.2 Eliwell Controller: Reset Factory
Parameter Settings
Contact Perlick.
8.6.3 Replacing Control Module
Tools required
8.6.3.1 Replacing Electro-mechanical Controller
STEP 1.
Remove evaporator fan panel. See Section 7.3.
STEP 2.
Remove 4 Phillips head screws holding fan and
electrical panel to cabinet back wall. Remove 2
Phillips head screws that mount control.
STEP 3.
When Controller is loose, turn over. Slide control
bulb pigtail out of zip tie and remove leads.
Return to
Table of Contents
STEP 4.
Reverse Steps 1 – 4 to replace control module.
Ensure control capillary tube does not touch other
objects and ensure pigtail is installed into zip tie and
secure.
8.6.3.2 Replacing Digital Controller – Dixell & Eliwell
STEP 1.
Remove 2 Philips head screws on rear flange of
control cradle.
STEP 2.
Remove wire harness plugs from cabinet side
walls.
Note: Remember correct location of leads and
orientation.
Electrical System Repair Instructions