PROBLEM
Water on the floor outside
of unit.
Water on the floor outside
of unit.
(continued)
Water on the floor inside
of unit.
Return to
Table of Contents
CAUSE
Refrigeration/Charge level is too low.
High ambient temperature and high am-
bient humidity conditions coupled with
frequent door opening.
Condensate pan overflowing.
Unit is not level.
Sealing compound does not form a com-
plete seal.
Door gasket is damaged.
Evaporator coil has iced over.
Evaporator pan and/or drain line restricted. Remove restriction.
Unit is not level.
Evaporator coil has iced over.
Troubleshooting Guide - Refrigeration System
SOLUTION
Check for leaks, repair, and recharge per
Section 7.13 and 7.14 .
Ensure doors close completely.
Remove excess water.
Check for the following:
• Air infiltration. See Section 7.1 .
• Doors close completely and seals are
intact. See Section 9.0 .
• Ice buildup. See Section 7.4 .
Unit must be level front-to-back and side-to-
side for water to drain properly.
Refer to Section 7.1 .
Refer to Sections 7.1 and 9.5 .
Remove ice. Refer to Section 7.4
Unit must be level front-to-back and side-to-
side for water to drain properly.
Remove ice. Refer to Section 7.4