Table 8-5. Hb24Fs Load Operation Modes; Table 8-6. Hc24Bb, Rb, Ro, Tb, To Wb Load Operation Modes; Table 8-7. Hc24Fs Load Operation Modes; Hb24Fs - Perlick HA24BB Service Manual

Residential and commercial front venting refrigeration
Hide thumbs Also See for HA24BB:
Table of Contents

Advertisement

Residential Refrigeration
and Front Venting Commercial Refrigeration
Service Manual

Table 8-5. HB24FS Load Operation Modes

Models: HB24FS
Temperature Control:
Defrost Style:
Cabinet Lighting:
LOAD
Compressor
Condenser Fan
Evaporator Fan
Hot Gas Solenoid Valve
*Defrost is elapsed time initiated and terminated (Timer)

Table 8-6. HC24BB, RB, RO, TB, TO WB Load Operation Modes

Models: HC24BB, RB, RO, TB, TO WB
Electronic Control:
Defrost Style:
Cabinet Lighting:
Evaporator Fan:
LOAD
Compressor
Condenser Fan
Evaporator Fan

Table 8-7. HC24FS Load Operation Modes

Models: HC24FS
Temperature Control: Electro-mechanical
Defrost Style:
Cabinet Lighting:
LOAD
COOLING
MODE
Energized
Compressor
Condenser Fan Energized
Evaporator Fan Energized
De-Energized
Hot Gas
Solenoid Valve
*Defrost is elapsed time initiated and terminated (Solid State Timer)
Return to
Table of Contents
Electro-mechanical
Hot Gas Defrost
Lights are controlled through a manual on/off switch as well as
through the door switch.
COOLING MODE
Energized
Energized
Energized
De-Energized
Eliwell (nEW961)
Off cycle defrost
Lights are controlled through a manual on/off switch as well as through
the door switch.
Is controlled by the door switch during Cooling Mode
COOLING MODE
Energized
Energized
Energized
Hot Gas Defrost
Lights are controlled through a manual on/off switch as well as through the door switch.
OFF MODE
De-Energized
De-Energized
De-Energized
De-Energized
Electrical System Repair Instructions
OFF MODE
De-Energized
De-Energized
De-Energized
De-Energized
OFF MODE
De-Energized
De-Energized
De-Energized
DEFROST
DEFROST
DELAY
(3-MINUTES)
TERMINATED)
De-Energized
Energized
De-Energized
Energized
De-Energized
Energized
Energized
Energized
DEFROST MODE
Energized
Energized
De-Energized
Energized
DEFROST MODE
N/A
N/A
N/A
DRIP
(TEMP
TIME
De-Energized
De-Energized
De-Energized
Energized
SIX HOUR
MANUAL
DEFROST
De-Energized
De-Energized
De-Energized
De-Energized
Page 8-19