I I I I I "CONTROLLER" → "PARAMETERS"
The parameters in the "CONTROLLER" menu are
divided into two groups: the global parameters and
the axis parameters. Both the general overview and
the details on all parameters and parameter
names with the respective factory settings can be
found in the chapter Software Reference, section
Parameters.
Or simply press [F1] when the mouse cursor is in
one of the input fields and you get information
about the corresponding parameter.
I I I I I Global parameters
The global parameters include the functions of the
inputs and outputs (GLI group) and the standard
parameters (GLS group). The corresponding inter-
nal parameter number is listed after the name of
the parameter. With these numbers, which are
listed consecutively in the next chapter, Parameter
Reference, you can find detailed information on
the global parameters.
Mark the VLT you wish to edit. You can change
each pre-set value individually. Click on "OK" to
load the changes in the VLT as the user para-
meters.
With "RESET" → → → → → "PARAMETERS" in the
"CONTROLLER" menu can reset all the factory
settings, however in doing so all parameters,
including the axis parameters, are reset to the
factory settings.
MG.10.J4.02 – VLT is a registered Danfoss trade mark
®
VLT
5000 SyncPos option
I I I I I Axis parameters
The axis parameters are always valid for all the
programs belonging to one controller. Click on
"CONTROLLER" → → → → → "PARAMETERS" → → → → → "AXIS"
and mark the controller the parameters of which
you want to view or change in the subsequent
dialog window. Also select the type in the field
"PARAMETERS":
Encoder
Home
Inputs / Outputs
PID-Controller
Synchronization
Velocity
For example Encoder
Encoder or Home:
Encoder
Encoder
Encoder
You can change each parameter and re-load it in
the VLT by clicking on "OK". But you can also im-
mediately select another VLT, change the parame-
ters and then load all the changes into the VLT
simultaneously with "OK".
The units of the parameter values and all other
information concerning the parameters can be
found in the Software Reference in the section
Parameters. This information is arranged according
to the internal parameter numbers (in increasing
order).
AXE
AXH
AXI
AXR
AXS
AXV
Home:
Home:
Home:
Home:
47