Danfoss VLT 5000 Series Manual page 130

Synchronizing and positioning option onizing and positioning option
Hide thumbs Also See for VLT 5000 Series:
Table of Contents

Advertisement

Parameter Code
Parameter Name
KILIM
Limit value for integral sum for
PID control
KINT
Integral value for PID control
KPROP
Proportional value for PID control
MENCODER
Resolution of the encoder 1 (master)
MENCODERTYPE Encoder type for encoder 0 (Master)
NEGLIMIT
Negative software limit switch
O_AXMOVE
Output for motion command active
O_BRAKE
Output for mechanical brake
O_ERROR
Output for error
POSDRCT
Rotational direction
POSERR
Maximum tolerated position error
POSFACT_N
Denominator user factor
POSFACT_Z
Numerator user factor
POSLIMIT
Positive software limit switch
POSUNITS
Unit for position display (UU)
PRGPAR
Activated program number
RAMPMIN
Shortest ramp
RAMPTYPE
Ramp type
REGWMAX
Size of the control window (activation)
REGWMIN
Size of the control window (deactivation)
REVERS
Reverse behavior for slave
SWNEGLIMACT
Negative software limit switch active
SWPOSLIMACT
Positive software limit switch active
SYNCACCURACY Size of the precision window for position synchronization 55
SYNCFACTM
Synchronization factor master (M:S)
SYNCFACTS
Synchronization factor slave (M:S)
SYNCFAULT
Marker number for fault
SYNCMARKM
Marker number for master
SYNCMARKS
Marker number for slave
SYNCMPULSM
Marker interval for master
SYNCMPULSS
Marker interval for slave
SYNCMSTART
Start behavior for marker synchronization
SYNCMTYPM
Marker type for master
SYNCMTYPS
Marker type for slave
SYNCMWINM
Tolerance window for master marker monitoring
SYNCMWINS
Tolerance window for lave marker monitoring
SYNCPOSOFFS
Position offset for positioning synchronization
SYNCREADY
Marker number for ready
SYNCVELREL
Tolerated deviance of the slave drive
from the master velocity in %
SYNCVFTIME
Velocity filter
TESTTIM
Time in target window
TESTVAL
Limit value for reading in target window
TESTWIN
Size of target window
TIMER
Sampling time for PID control
VELMAX
Maximum velocity
VELMAXQC
Maximum velocity (internal parameter)
VELRES
Velocity resolution
130
VLT
®
5000 SyncPos option
VLT-SyncPos
Par.
No. Par.No.
Group
705
21
AXR
704
13
AXR
702
11
AXR
30
AXE
67
AXE
4
AXI
64
AXI
48
AXI
108
GLS
28
AXE
15
AXR
26
AXE
23
AXE
5
AXI
29
AXE
701
102
GLS
31
AXV
32
AXV
38
AXR
39
AXR
63
AXR
19
AXI
20
AXI
AXS
49
AXS
50
AXS
57
AXS
52
AXS
53
AXS
58
AXS
59
AXS
62
AXS
60
AXS
61
AXS
68
AXS
69
AXS
54
AXS
56
AXS
66
AXS
709
65
AXS
24
AXI
25
AXI
8
AXI
14
AXR
1
AXV
9
AXV
22
AXV
MG.10.J4.02 – VLT is a registered Danfoss trade mark
Unit
Factory
Setting
0
0
30
counts/
500
revolution
0
qc
–500000
0
0
0
1
qc
20000
1000
1000
qc
500000
0
– 1
msec
1000
0
qc
0
qc
0
0
0
0
qc
1000
qc
1
qc
1
10
1
1
qc
500
qc
500
0
0
0
qc
0
qc
0
qc
0
1
%
0
τ_filt (µsec)
0
ms
0
qc
1
qc
0
msec
1
Rpm
3000
qc/ms *
1/65536
100