I I I I I How SyncPos functions
Let us explain the basic principle of SyncPos in
brief:
Determining parameters
Factory settings are stored in the program for all
parameters. These factory settings are active upon
delivery and can be re-activated at any time by
performing a reset (see page 42).
You can adjust all the parameters for your con-
troller. These user parameters are permanently
saved in the EEPROM and are valid for all
programs.
Before you start programming it is necessary to
determine basic parameters of the VLT connected,
Maximum velocity
Maximum velocity
such as Maximum velocity
Maximum velocity
Maximum velocity VELMAX (1) and
Shortest ramp RAMPMIN (31), set the PID filter
Shortest ramp
Shortest ramp
Shortest ramp
Shortest ramp
values and define the User factor
User factor with
User factor
User factor
User factor
POSFACT_Z (23) and POSFACT_N (26).
Within a program you can temporarily alter the
parameters with the command SET. After running
the program these values are once again replaced
with the user parameters which have been saved.
Programming with the SyncPos macro-language
In the "EDIT" menu you can create and comment
on the programs just like in a text program. All
commands are described in detail in the Chapter
Software Reference.
Each command consists of a COMMAND WORD
+ parameter
parameter
parameter
parameter (if necessary), whereas the parameter
parameter
can be a variable, constant or an array.
Comments are written between /* ... */ or after //
for example:
POSA 3000
/* axis absolute to actual zero point move to
position 3000 */
// axis absolute to actual zero point move to
position 3000
It is particularly easy to write your program by
using the "COMMAND LIST". Once you have se-
lected the command, all the necessary input fields
are immediately opened. After entering the values
the syntax is automatically formed and you can
insert the entire command in your program.
With teach-in programming you simply move the
axis to the desired position and store the position
which has been reached. In this manner you can
quickly program the most complicated adjust-
ments and sequences of movements.
MG.10.J4.02 – VLT is a registered Danfoss trade mark
®
VLT
5000 SyncPos option
Running and testing programs
In the "DEVELOPMENT" menu you can test new
programs. The program is loaded into the VLT and
started only after the "EXECUTE" function has been
activated. Naturally, you can run the program being
tested in "SINGLE STEPS" or start the program at a
certain point and have it executed step-by-step.
Before every run a new program is automatically
checked to ensure that the commands are correct.
Or you can start the "SYNTAX CHECK" without
running the program.
Saving programs in the VLT
Every time you Execute a program or start the
syntax check, this program is temporarily stored in
the RAM in an area that is always overwritten with
every subsequent test.
Once you have finished writing a program for the
SyncPos option, the temporary program can be saved
permanently in EEPROM. It will then be assigned a
number or name and can be tagged with "AUTOSTART"
so it automatically will be started after turning on the VLT.
This way you can drive the VLT offline.
All programs can also be started using the program
number via the inputs, for example from a PLC. For
this the inputs must be set accordingly with
"CONTROLLER" → → → → → "PARAMETERS" → → → → → "GLOBAL".
Optimizing the controller with the control
parameters
The position control unit integrated in the SyncPos
option automatically calculates a theoretical set
course during each sequence of movements and
tries to control the VLT or the motor so that the
best possible convergence to the set course is
achieved. By means of the control parameters you
can directly influence to what degree and how
quickly a deviation from the theoretical set course
is counteracted.
These PID filter parameters can also, theoretically,
be determined if you have comprehensive know-
ledge of the entire drive, including the load con-
nected. However, the experimental method with
the functions in the "TESTRUN" menu is conside-
rably faster and simpler.
After every "TESTRUN" it is also possible to eva-
luate the control parameters on the basis of four
graphics: they show the actual and set curves for
the velocity, the acceleration, the position and the
power curve. Thus, you can successively adjust the
PID filter parameters and optimize the controller.
We wish you the best in your work with SyncPos!