All Syncpos Parameters In Detail; Parameter Group; Unit; Value Range - Danfoss VLT 5000 Series Manual

Synchronizing and positioning option onizing and positioning option
Hide thumbs Also See for VLT 5000 Series:
Table of Contents

Advertisement

I I I I I All SyncPos Parameters in Detail
The sequence of parameters is determined by the
internal parameter number. We recommend using
the overview as a guide; then you will be able to
find detailed information very quickly using the in-
ternal parameter number.
General Information on the Parameter Values
Some limiting values are listed at 1 billion to make
them more easily readable. However, the exact
value is 1,073,741,824.
NB!
The unit defined by the parameter User
factor
factor
factor
factor POSFACT_Z (23) and POSFACT_N
factor
(26) is not used for all path and position parame-
ters. For various parameters (for example a soft-
ware limit switch like I_POSLIMITSW (46) and the
parameter T T T T T olerated position error
olerated position error
olerated position error
olerated position error POSERR(15)
olerated position error
the quad-count unit (qc) is valid.
4 quad-counts correspond to one sensor unit.
Abbreviation
For a description which is not dependent on the
version or the hardware, variables were used in the
following section for some limit values: thus the
value of

MLONG = 1.073.741.824

Factory settings
Each factory setting is marked with #.
Input range
Whether the input range listed is exceeded is not
checked by the program, since due to the large
domain there is no suitable test possibilities.
NB!
Even within the areas indicated illogical
inputs can result from the large differences
in performance of the motors and the wide variety
of possible applications. Therefore, it is the
responsibility of the programmer and the user to
observe the performance ranges of the drive and
of the system.
MG.10.J4.02 – VLT is a registered Danfoss trade mark
®
VLT
5000 SyncPos option
1
VELMAX
VELMAX defines the rated speed of the drive. This
value is listed in Rpm and is needed for the calcu-
lation of ramps and actual velocities.
NB!
The nominal speed refers to the speed of
the encoder.
Content
Rated speed of the drive
User
User
User
User

Parameter Group

AXV

Unit

Rpm

Value range

1 ... 65535
# 3000
131

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents