Danfoss VLT 5000 Series Manual page 156

Synchronizing and positioning option onizing and positioning option
Hide thumbs Also See for VLT 5000 Series:
Table of Contents

Advertisement

I I I I I VLT and SyncPos option messages
All messages are shown in the LCP display of the
VLT in short and in the SyncPos software in plain
text.
You can find brief information on the error
messages in the table or detailed information in
the following section.
I I I I I Table of Messages
The tables contain the messages in numerical
order. Letters following a % sign represent
variables which can be used in plain text at the
corresponding locations.
O.ERR_
LCP-Display
3
AXES NOT IN SYSTEM
5
ERROR NOT CLEARED
6
HOME NOT EXECUTED
7
HOME_VEL ZERO
8
POSITION ERROR
9
INDEX NOT FOUND
10
UNKNOWN COMMAND
11
SOFTWARE LIMIT ACT.
12
ILLEGAL PARAMET. NO
13
General VLT error
14
TOO MANY NEST. LOOP
16
PARAM. ERROR EEPROM
17
PROGR. ERROR EEPROM
18
RESET BY CPU
19
USER ABORT
25
LIMIT SWITCH ACTIV.
51
TOO MANY NEST. GOSUB
52
TOO MANY RETURN
62
ERROR IN VERIFYING
70
ERROR IN DIM COMMD
71
ARRAYBOUNDS CROSSED
79
TIMEOUT WAITNDX
84
TOO MANY ONTIME
87
OUT OF MEMORY (VAR)
90
MEMORY locked
xx
INTERNAL ERROR
156
VLT
®
5000 SyncPos option
SyncPos message
Axis no. %bu not in system
Axis no: 1 Error not cleared
Axis no: 1 Failed to move to HOME position
Axis no: 1 Home vel 0
Axis no: 1 Position error
Axis no: 1 Index pulse (encoder) not found
Unknown command
Axis no.1 Software limit switch activated
Illegal parameter number
General VLT error
Too many nested loops
Parameters in EEPROM are corrupted
Programs in EEPROM are corrupted
Reset by CPU
User abort
Axis no. 1 Limit switch activated
Too many nested GOSUB commands
Too many RETURN commands
EEPROM: address % defect
Error in DIM command
Attempt was made to cross arraybounds
Timeout while waiting for index
Too many time interrupts
No more room for variables
The program memory is write-protected.
Internal error ##
MG.10.J4.02 – VLT is a registered Danfoss trade mark

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents