Vlt Parameter List - Danfoss VLT 5000 Series Manual

Synchronizing and positioning option onizing and positioning option
Hide thumbs Also See for VLT 5000 Series:
Table of Contents

Advertisement

I I I I I VLT parameter list
PNU Parameter
description
700
System control
701
Program number
702
PID, Proportional factor
703
PID, Derivative factor
704
PID, Integral factor
705
PID, Integral bandwidth
706
PID, BANDWIDTH
707
PID, Velocity Feed-forward
708
PID, Acceleration Feed-forward
709
PID, Velocity filter
710
User parameter 10
711
User parameter 11
...
778
User parameter 78
779
User parameter 79
780
Activated dead time compensation
795
User parameter 95 (read only)
796
User parameter 96 (read only)
797
User parameter 97 (read only)
798
User parameter 98 (read only)
799
User parameter 99 (read only)
Changes during operation
"Yes" means that the parameter can be changed, while the VLT frequency converter is in operation. "No"
means that the VLT frequency converter must be stopped before a change can be made.
4-Setup
"Yes" means that the parameter can be programmed individually in each of the four setup's, i.e. the same
parameter can have four different data values. "No" means that the data value will be the same in all four
setup's.
Conversion index
The conversion index is used when transferring parameter values with decimals by means of serial commu-
nication. Conversion index 0 means that the parameter value is multiplied by 1.
Data type
Indicates the data type of the parameter value. Data type 4
Unsigned 16bit.
Unsigned 16bit
Unsigned 16bit
Unsigned 16bit
Unsigned 16bit
1) The maximum range is -2
eter in the application program using LINKGPAR or LINKAXPAR.
128
Factory
settings
-1
30
0
0
1000
1000
0
0
0
0
0
0
0
OFF
0
0
0
0
0
Data type 4 is an Integer 32bit
Data type 4
Data type 4
Data type 4
32
to 2
32
-1 (-2147483648 to 2147483647) but the actual range is specified when defining a user param-
VLT
®
5000 SyncPos option
Range
Changes
during
Operation
0 - 1
Yes
-1 - 127
Yes
0 - 65000
Yes
0 - 65000
Yes
0 - 65000
Yes
0 - 1000
Yes
0 - 65000
Yes
0 - 65000
Yes
0 - 65000
Yes
0 - 65000
Yes
Defined by user
1
Yes
Defined by user
1
Yes
Defined by user
1
Yes
Defined by user
1
Yes
0 - 1
No
Defined by user
1
Read only
Defined by user
1
Read only
Defined by user
1
Read only
Defined by user
1
Read only
Defined by user
1
Read only
Integer 32bit
Integer 32bit and data type 6
Integer 32bit
Integer 32bit
MG.10.J4.02 – VLT is a registered Danfoss trade mark
4-Setup
Con- Data
version type
index
No
0
6
No
0
4
No
0
4
No
0
4
No
0
4
No
0
4
No
0
4
No
0
4
No
0
4
No
0
4
No
0
4
No
0
4
No
0
4
No
0
4
No
0
6
No
0
4
No
0
4
No
0
4
No
0
4
No
0
4
data type 6
data type 6 is an
data type 6
data type 6

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents