Danfoss VLT 5000 Series Manual page 115

Synchronizing and positioning option onizing and positioning option
Hide thumbs Also See for VLT 5000 Series:
Table of Contents

Advertisement

I I I I I SYSVAR
The system variable SYSVAR – a prepared pseudo
array – provides detailed system information. You
also need this index if you link the system variable
with the LCP display using LINKSYSVAR or specify
recording data of a test run with TESTSETP .
Summary
System variable (Pseudo array) reads system
values.
Syntax
SYSVAR[n]
n = index
System Process Data
Index Description
1
Input Byte 0 (I1 ... I8)
2
Input Byte 1 (VLT input 16 ... 33)
9
Output Byte 0
17
Top 2 bytes which are provided by the
SyncPos command STAT
22
Value which is also supplied by the
SyncPos command TIME
28
Actual motor current
30
Motor voltage
31
VLT status word
32
Actual output frequency
33
current line number of the SyncPos pro-
gram in case of #DEBUG NOSTOP
Axis Process Data
Index Description
4096
Current position slave in qc (without con-
version to UU) (see APOS)
4097
Set position slave in qc (without conver-
sion to UU) (see CPOS)
4098
Last slave index position in qc (without
conversion to UU) (see IPOS)
4099
Actual velocity in qc/st, where st is the
sample time set by _GETVEL.
4100
Current velocity Master (as above)
4101
Current position error in qc
4102
Contains the number of revolutions of the
encoder after the first overflow of the ab-
solute encoder, provided the graduation
per revolution is entered correctly in EN-
CODER (2).
4103
As above for the master
4105
Current master position without conversion
(qc) (see MAPOS)
4106
Last Master index position without conver-
sion (qc) (see MIPOS)
MG.10.J4.02 – VLT is a registered Danfoss trade mark
®
VLT
5000 SyncPos option
4107
Internal current velocity (ACTPOS – last
ACTPOS) (qc/1 ms)
4108
Internal Master velocity (see above)
4109
Current frequency of the master simulation
(1/1000 Hz) (see PULSVEL)
4110
Determines whether the master simulation
is active or not (1 or 0)
4111
REG_REFERENCE Actual set value
which is output by the control through the
position controller (between –FFFFF and
FFFFF resp. –1048575 and 1048575 deci-
mal)
Axis Process Data, Profile generator value
Index Description
4218
Returns all 32 flags of the profile generator.
These are:
PG_FLAG_BUSY
// Flag for busy information
PG_FLAG_COMMANDERR2L
// Flag for Command Error occurred (not
used)
PG_FLAG_POSREACHED 4L
// Flag for Position reached
PG_FLAG_INDEX_HIT
// Flag for Index observed
PG_FLAG_WRAP_OCC
// Flag for Wraparound occurred (not used)
PG_FLAG_POS_ERR
// Flag for Position Error occurred
PG_FLAG_BRKPT_RCHD 64L
// Flag for Breakpoint reached (not used)
PG_FLAG_FLOATING
// Flag for MOTOR OFF
1L
8L
16L
32L
128L
115