Synchronizing and positioning option onizing and positioning option
Hide thumbs Also See for VLT 5000 Series:
Table of Contents

Advertisement

MIPOS
queries last index or marker
position of the master
IPOS
queries last index or marker
position of the slave
MAVEL
queries actual velocity of the
master
AVEL
queries actual velocity of an
axis
TRACKERR
queries actual position error of
the axis
SYNCERR
queries actual synchronization
error of the slave
E R R N O
reads error number
I N
reads input bit-by-bit (individually)
I N B
reads input by bytes (units of 8)
INAD
reads analog input
INKEY
reads key codes of VLT
OUT
sets output bit-by-bit (single)
OUTAN
sets VLT reference
OUTB
sets output by bytes (units of 8)
OUTDA
sets analog output (freely available)
PID
completes PID calculation
PRINT
output (display) texts and
variables
STAT
reads axis status
TESTSETP
Specify recording data for test run
TESTSTART
Start the recording of a test run
TIME
reads internal controller time
_GETVEL
changes sample time for AVEL
and MAVEL
Interrupt Functions (INT)
DISABLE ...
switches interrupt ... off
DISABLE ALL
switch off all interrupts except
ON ERROR
ENABLE ...
switches interrupt ... on
ENABLE ALL
switches all interrupts on
ON COMBIT .. GOSUB
call up a subprogram when Bit n of
the communication buffer is set
ON ERROR GOSUB
calls subroutine in the event of
an error
ON IN .. GOSUB calls subroutine depending on
input signal
ON PARAM .. GOSUB
call up a subprogram when a
parameter is altered
ON PERIOD .. GOSUB
calls subroutine at regular intervals
ON STATBIT
call up a subprogram when bit n
of the VLT status is set
ON TIME
calls subroutine after single
timing
MG.10.J4.02 – VLT is a registered Danfoss trade mark
®
VLT
5000 SyncPos option
Parameter (PAR)
All global and axis parameters with a parameter
code can be set and read with the following com-
mands. (Parameter code see overview in
Parameter Reference.)
GET
reads SyncPos parameter
values (axis, global and user
parameters)
GETVLT
reads VLT parameter values
SET
sets SyncPos parameter values
(axis, global and user parameter)
SETVLT
sets VLT parameter values
LINKAXPAR
links axis parameter with LCP
display
LINKGPAR
links global parameter with LCP
display
LINKSYSVAR
links system variable with LCP
display
Communication option
COMOPTSEND
writes in the Communication
option buffer
COMOPTGET
reads a Communication option
telegram
PCD
pseudo array for direct access
to the fieldbus data area
Relative Motion (REL)
Commands for the relative positioning of the axis
ACC
sets acceleration
DEC
sets deceleration
POSR
positioning relative to the actual
position
VEL
sets velocity
Synchronization (SYN)
Commands to synchronize the slave with the
master or the master simulation
MOVESYNCORIGIN
relative shifting of the origin of
synchronization
SYNCV
synchronization of velocity
SYNCP
synchronization of angle/position
SYNCM
synchronization of angle/
position with marker correction
SYNCSTAT
queries flag for synchronization
status
SYNCSTATCLR
resetting of the flags MERR and
MHIT
PULSACC
sets acceleration for the virtual
master
PULSVEL
sets velocity for the virtual
master