Danfoss VLT 5000 Series Manual page 160

Synchronizing and positioning option onizing and positioning option
Hide thumbs Also See for VLT 5000 Series:
Table of Contents

Advertisement

160
VLT
®
5000 SyncPos option
O.ERR_71
SyncPos
Attempt was made to cross arraybounds
Meaning
An attempt was made to describe an array ele-
ment that is located outside of the defined array
limits.
Cause
Error in the SyncPos program. Array sizing does not
agree with the space required (e.g. due to an in-
correctly programmed loop).
Or the array is too small for the number of test runs
triggered by TESTSTART.
Tip
Check loop variables.
O.ERR_79
SyncPos
Timeout while waiting for index.
Meaning
The command WAITNDX was executed and
the timeout listed was exceeded.
Cause
The timeout is probably too short or the index
impulse could not found (see also O.ERR_9).
O.ERR_84
SyncPos
Too many time interrupts
Meaning
Too many ON TIME or ON PERIOD commands
were used within the program.
Tip
A maximum of 12 of these ON TIME and/or ON
PERIOD commands are allowed within one
program. . . . .