Digital inputs
MK3A is a 10pole terminal block with 8 digital
inputs (I1–I8) and 2 terminals for 24 V supply (See
Supply voltages on page 12).
The digital inputs are used by the SyncPos appli-
cation program and are therefore free progra-
mable. All the inputs can also be assigned func-
tions by the following parameters:
I_BREAK (105)
I_BREAK
I_BREAK
interrupt a running
I_BREAK
I_BREAK
program
I_CONTINUE
I_CONTINUE
I_CONTINUE (106)
I_CONTINUE
I_CONTINUE
restart interrupted
program
I_ERRCLR
I_ERRCLR
I_ERRCLR
I_ERRCLR (107)
I_ERRCLR
reset fault
I_NEGLIMITSW
I_NEGLIMITSW
I_NEGLIMITSW (47)
I_NEGLIMITSW
I_NEGLIMITSW
negative limit switch
I_POSLIMITSW
I_POSLIMITSW
I_POSLIMITSW (46)
I_POSLIMITSW
I_POSLIMITSW
positive limit switch
I_PRGCHOICE
I_PRGCHOICE (104)
I_PRGCHOICE
selection of SyncPos
I_PRGCHOICE
I_PRGCHOICE
program
I_PRGSTAR
I_PRGST
I_PRGST
I_PRGST
I_PRGST
AR
AR
ART T T T T (103)
AR
start of SyncPos program
I_REFSWITCH
I_REFSWITCH
I_REFSWITCH
I_REFSWITCH
I_REFSWITCH (45)
home switch
Only two of the inputs are assigned a specific
function by parameter:
• • • • • I5 I5 I5 I5 I5 is used as marker input for the Master
when "External marker signal" is selected in
parameter SYNCMTYPM
SYNCMTYPM (60).
SYNCMTYPM
SYNCMTYPM
SYNCMTYPM
• • • • • I6 I6 I6 I6 I6 is used as marker input for the Slave when
"External marker signal" is selected in param-
SYNCMTYPS
SYNCMTYPS
eter SYNCMTYPS
SYNCMTYPS
SYNCMTYPS (61).
Digital outputs
MK3C is a 10pole terminal block with 8 digital out-
puts and 2 terminals for 24 V supply (See Supply
voltages on page 12).
The digital outputs are controlled by the SyncPos
application program and are thus free
programable.
All the outputs can also be assigned functions by
the following parameters:
O_AXMOVE (64)
O_AXMOVE
O_AXMOVE
O_AXMOVE
O_AXMOVE
axe is moving
O_BRAKE (48)
O_BRAKE
O_BRAKE
O_BRAKE
O_BRAKE
activation of mechanical
brake
O_ERROR (108)
O_ERROR
O_ERROR
O_ERROR
O_ERROR
fault indication
Terminal
A1
Incremental input
A in
Absolute input
Clk out
Virtual master
A out
Fig. 1
MG.10.J4.02 – VLT is a registered Danfoss trade mark
®
VLT
Encoder interface 1
MK3B is a 8pole terminal block with 6 terminals
for the encoder signals and 2 terminals with 5 V
supply.
(See Supply voltages on page 12).
Encoder interface 1 can be used for one of the
following 2 functions:
• • • • • Master encoder input (incremental or abso-
lute) for synchronizing.
• • • • • Virtual master encoder output (incremental).
The table below shows the function of each termi-
nal in the 3 possible modes. (See fig. 1)
options except on the first and the last station
connected in the network. See also connection
example on page 16 and 17.
Encoder interface 2
MK3D is a 8pole terminal block with 6 terminals
for the encoder signals and 2 terminals with 5 V
supply
(See Supply voltages on page 12).
Encoder interface 2 can be used for one of the
following 2 functions:
• • • • • Slave encoder input (incremental or absolute)
for synchronizing.
• • • • • Feedback encoder input (incremental or ab-
solute) for positioning.
The table below shows the function of each
terminal in the 2 possible modes. (See fig. 2, next
page)
A1
B1
A in
B in
Clk out
Data in
A out
B out
5000 SyncPos option
NB!
When using the virtual master function termi-
nation must be switched off (sw 1.2-1.4) in all
B1
Z1
B in
Z in
Data in
Not used
B out
Z out
Z1
Z in
Not used
Z out