Maintenance 9. Troubleshooting
No.
The Fieldbus I/O driver is in an abnormal
9233
state.
9234
Fieldbus I/O driver initialization failure.
RAS circuit detected a servo system
9610
malfunction. Reboot the controller.
Check for noise. Replace the controller.
Servo CPU internal RAM failure. Reboot
9611
the controller. Check for noise. Replace
the DMB.
RAM for the main and servo CPU
communication
9612
controller. Check for noise. Replace the
DMB.
Servo CPU internal RAM failure. Reboot
9613
the controller. Check for noise. Replace
the DMB.
Initialization communication of main CPU
and servo CPU failure.
9614
Controller.
Check for noise.
DMB.
Initialization communication of the main and
9615
servo CPU failure. Reboot the controller.
Check for noise. Replace the DMB.
Communication of the main and servo CPU
9616
failure. Reboot the controller. Check for
noise. Replace the DMB.
Communication of the main and servo CPU
9617
failure. Reboot the controller.
Check for noise. Replace the DMB.
9618
Servo long time command overrun.
9619
Servo long time command check sum error.
System watchdog timer detected a failure.
9620
Reboot the controller.
Replace the DMB.
9621
Drive unit check failure.
RAM failure of the servo CPU. Reboot the
9622
controller. Check for noise. Replace the
DMB.
Failure of the redundant circuitry for the
9623
emergency stop or the safeguard.
the wiring.
Low voltage of the main circuit power
9624
supply was detected.
supply voltage. Reboot the controller.
Control relay contact of the main circuit
9625
power supply is welded closed.
the DPB.
Servo real time status failure.
9630
Check sum error.
192
Message
failure.
Reboot
the
Reboot the
Replace
Check for noise.
Check
Check the power
Replace
Remedy
The module is broken or the controller
software is damaged. Restore the controller
firmware.
The module is broken or the controller
software is damaged. Restore the controller
firmware.
Check the noise countermeasures.
Replace the DMB.
Check the noise countermeasures.
Replace the DMB.
Check the noise countermeasures.
Replace the DMB.
Check the noise countermeasures.
Replace the DMB.
Check the noise countermeasures.
Replace the DMB.
Check the noise countermeasures.
Replace the DMB.
Check the noise countermeasures.
Replace the DMB.
Check the noise countermeasures.
Replace the DMB.
Check the noise countermeasures.
Replace the DMB.
Check the noise countermeasures.
Replace the DMB.
Check the noise countermeasures.
Replace the DMB.
Check the noise countermeasures.
Replace the DMB.
Check the noise countermeasures.
Replace the DMB.
Check the noise countermeasures.
Replace the DMB.
Check the noise countermeasures.
Replace the DMB.
Replace the DMB.
Reboot the controller.
Replace the DMB.
Check the noise countermeasures.
Note 1