Epson RC90 User Manual page 202

Robot controller. epson rc+ 7.0
Hide thumbs Also See for RC90:
Table of Contents

Advertisement

Maintenance 9. Troubleshooting
No.
GUI Builder.
7600
Cannot execute a GUI Builder statement
from the command window.
GUI Builder.
7602
GSet parameter is too long.
GUI Builder.
7603
Too many parameters for GGet.
GUI Builder.
7604
Not enough data for GGet statement
variable assignment.
GUI Builder.
The event task cannot be executed.
7610
System
in
EventTaskType is Normal.
GUI Builder.
The event task cannot be executed.
7611
Safeguard is open and EventTaskType is
Normal.
GUI Builder.
The event task cannot be executed.
7612
Estop is active and EventTaskType is not
NoEmgAbort.
GUI Builder.
The event task cannot be executed.
7613
System in error state and EventTaskType
is not NoEmgAbort.
GUI Builder.
7650
Invalid property.
GUI Builder.
7651
Invalid form.
GUI Builder.
7652
Invalid control.
GUI Builder.
7653
The specified form is already open.
GUI Builder.
7654
Event function does not exist.
GUI Builder.
7655
Item does not exist.
GUI Builder.
7656
Invalid property value.
Security.
7700
Invalid user.
Security.
7701
Invalid password.
Security.
7702
Permission denied.
Security.
7703
Option not active.
7710
Source and destination cannot be the
same.
7711
Point file name is used by another robot.
7712
Invalid axis specified.
186
Message
pause
state
and
Remedy
Correct the parameter to the proper
length.
Check the number of parameters.
Specify the variable.
The system can be operated by
changing EventTaskType to "NoPause"
The system can be operated by
changing
EventTaskType
"NoEmgAbort"
The system can be operated by
changing
EventTaskType
"NoEmgAbort"
The system can be operated by
changing
EventTaskType
"NoEmgAbort"
Specify the valid property.
Specify the valid form.
Specify the valid control.
Modify the program to avoid double
launch.
Check the function name set for the
event.
Specify the valid item.
Check the property value and specify
the valid value.
Contact the administrator to register the
user
Check the password.
Contact
the
administrator
authority.
Register the options.
Specify another destination.
Check the point file name.
Check whether the specified axis is
valid. Check if the axis is specified
correctly.
Note 1
to
to
to
to
set