Epson RC90 User Manual page 155

Robot controller. epson rc+ 7.0
Hide thumbs Also See for RC90:
Table of Contents

Advertisement

No.
Message
Cannot execute a Dll Call statement
2326
from the command window.
2327
Failed to execute a Dll Call.
Cannot
execute
2328
connection with RC+.
Cannot execute an Eval statement in a
2329
Trap Call process.
Trap failure.
2330
Cannot use the argument in Trap Call
or Xqt statement.
Trap failure.
2331
Failed to process Trap Goto statement.
Trap failure.
2332
Failed to process Trap Goto statement.
Trap failure.
2333
Trap is already in process.
Cannot execute an Eval statement in a
2334
Trap Finish or a Trap Abort process.
Cannot continue execution and Reset
2335
Error in TEACH mode.
Cannot use Here statement with a
2336
parallel process.
Cannot execute except from an event
2337
handler functions of GUI Builder.
Cannot execute Xqt, data input, and
2338
output for TP in a TEST mode.
2339
Cannot execute in stand-alone mode.
Specified value in InBCD function is
2340
an invalid BCD value.
Specified
value
2341
statement is an invalid BCD value.
Cannot change the status for output bit
2342
configured as remote output.
Output time for asynchronous output
2343
commanded by On or Off statement is
out of the available range.
I/O input/output bit number is out of
2344
available range or the board is not
installed.
I/O input/output byte number is out of
2345
available range or the board is not
installed.
I/O input/output word number is out of
2346
available range or the board is not
installed.
Memory I/O bit number is out of
2347
available range.
RC90 (EPSON RC+ 7.0) Rev.4
Execute DII Call from the program.
Check the DLL.
Review the program.
the
task
before
You need to connect with RC+ before
executing the task.
Check the program.
Check the program.
Rebuild the project.
Rebuild the project.
Rebuild the project.
Check the program.
Check the program.
Go Here :Z(0) ! D10; MemOn(1) !
is not executable.
Change the program to:
P999 = Here
Go P999 Here :Z(0) ! D10; MemOn(1) !
Review the program.
Cannot execute in TEST mode.
Review the program.
Chenge the setting to "cooperative
mode" and execute.
Review the program.
in
the
OpBCD
Review the program.
Check the remote I/O setting.
Review the program.
Review the program.
Check whether the expansion I/O board
and Fieldbus I/O board are correctly
detected.
Review the program.
Check whether the expansion I/O board
and Fieldbus I/O board are correctly
detected.
Review the program.
Check whether the expansion I/O board
and Fieldbus I/O board are correctly
detected.
Review the program.
Maintenance 9. Troubleshooting
Remedy
Note 1
Note 2
Tens digit
Units digit
The
specified
value
1: bit, 2: byte,
I/O number
3: word
The
specified
time
Bit number
Byte number
Word number
Bit number
139