Epson RC90 User Manual page 162

Robot controller. epson rc+ 7.0
Hide thumbs Also See for RC90:
Table of Contents

Advertisement

Maintenance 9. Troubleshooting
No.
RS-232C
port
2934
completed.
Data received from the RS-232C port
2935
is beyond the limit of one line.
Cannot
execute
2937
RS-232C are using.
Cannot execute while ModBus are
2938
using.
Daemon failure. Failed to create the
2950
daemon thread.
Daemon failure.
2951
creating the daemon thread.
TEACH/AUTO switching key input
2952
signal failure was detected.
ENABLE key input signal failure was
2953
detected.
2954
Relay weld was detected.
Temperature of regeneration resistor
2955
was
higher
temperature.
MNG failure.
2970
Area allocate error.
MNG failure.
2971
Real time check error.
MNG failure.
2972
Standard priority error.
2973
MNG failure. Boost priority error.
2974
MNG failure. Down priority error.
2975
MNG failure. Event wait error.
2976
MNG failure. Map close error.
2977
MNG failure. Area free error.
2978
MNG failure. AddIOMem error.
2979
MNG failure. AddInPort error.
2980
MNG failure. AddOutPort error.
2981
MNG failure. AddInMemPort error.
MNG failure.
2982
AddOutMemPort error.
2983
MNG failure. IntervalOutBit error.
2984
MNG failure. CtrReset error.
2997
Collision Detection
AbortMotion attempted when robot
2998
was not moving
146
Message
connection
not
while
Remote
Timeout while
than
the
specified
Remedy
Check the RS-232C port.
The maximum length of a line is 255
bytes.
Specified port is currentlu used.
Specify another port.
Specified port is currentlu used.
Specify another port.
Reboot the Controller.
Reboot the Controller.
Set the TP key switch to TEACH or
AUTO properly. Check whether the TP
is connected properly.
Check whether the TP is connected
properly.
Overcurrent probably occurred due to
short-circuit failure.
Investigate the
cause of the problem and take necessary
measures and then replace the DPB.
Check whether the filter is not clogged
up and the fan does not stop.
If there is no problem on the filter and
fan, replace the regenerative module.
Reboot the Controller.
Reboot the Controller.
Reboot the Controller.
Reboot the Controller.
Reboot the Controller.
Reboot the Controller.
Reboot the Controller.
Reboot the Controller.
Reboot the Controller.
Reboot the Controller.
Reboot the Controller.
Reboot the Controller.
Reboot the Controller.
Reboot the Controller.
Reboot the Controller.
If you use the simulator, check if the
object is placed in the direction of the
robot motion.
See Help for AbortMotion.
Note 1
The number of
bytes
in
a
received line
RC90 (EPSON RC+ 7.0) Rev.4
Note 2

Hide quick links:

Advertisement

Table of Contents
loading