Epson RC90 User Manual page 135

Robot controller. epson rc+ 7.0
Hide thumbs Also See for RC90:
Table of Contents

Advertisement

No.
Message
Operation Failure.
1001
Command parameter is invalid.
Requested data cannot be accessed.
1002
The data is not set up or the range is
invalid.
1003
The password is invalid
Cannot execute with unsupported
1004
version.
Cannot execute with invalid serial
1005
number.
Cannot execute with invalid Robot
1006
model.
Cannot
execute
1007
Controller.
Initialization
failure.
1008
initialize TP.
Remote setup error.
1010
Cannot assign R-IO input number to
remote input.
Remote setup error.
Cannot assign a bit number which
1011
does not exist to a remote I/O signal.
Check the fieldbus slave size.
Remote setup error.
Cannot assign a bit number which
1012
does not exist to a remote I/O signal.
Check the fieldbus master size.
Fieldbus slave failure.
1013
Cannot change the size because it
currently includes a remote I/O signal.
Fieldbus
master
1014
change the size because it currently
includes a remote I/O signal.
1020
Cannot execute in recovery mode.
Cannot execute due to controller
1021
initialization failure.
Cannot execute without the project
1022
being open.
Cannot execute while the project is
1023
open.
1024
Cannot activate from remote.
Execution
in
1025
prohibited.
Cannot execute in Teach mode except
1026
from TP.
1027
Cannot execute in Auto mode.
Cannot execute in Auto mode except
1028
from the main console.
1029
Cannot execute from OP.
Does not allow Operation mode to be
1030
changed.
Cannot
execute
1031
executing.
RC90 (EPSON RC+ 7.0) Rev.4
Check whether the target I/O, variables,
and tasks exist.
Enter the correct password.
Use the correct version file.
Use the backup data for the same
controller to restore the controller
configuration.
Use the backup data for the same
controller to restore the controller
configuration.
with
invalid
Use the supported installer.
Failed
to
Specify the input number excluding the
R-IO input number.
Check the fieldbus slave size.
Check the fieldbus master size.
-
failure.
Cannot
-
Boot the controller as normal.
Restore the controller configuration.
Open a project.
Rebuild the project.
Enable the remote input.
Teach
mode
is
Change to the AUTO mode.
Change to the AUTO mode.
Change to the Program mode.
Change to the Program mode.
Enable the OP input.
Change to the Auto mode with a console
in the Program mode.
while
tasks
are
Stop the task and then execute.
Maintenance 9. Troubleshooting
Remedy
Note 1
Note 2
119

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents