Chapter 3 Provisioning and Operating the SSU-2000e
Initial Provisioning
3. Provision the Output module as appropriate.
ICS command:
Refer to the OUTPUT command description in the SSU-2000e Technical
Reference for details on all command options.
TL1 command:
Refer to the SET-PRMTR-OUT commands for the various Output modules in the
SSU-2000e Technical Reference.
4. DIsable unused output ports to prevent spurious alarms. Repeat this command
for each shelf, port, and slot.
ICS command:
Type
OUTPUT xAy-z DISABLE
where x is the shelf number, y is the slot number, and z is the port number.
TL1 command:
SET-PRMTR-OUTPUT::SxAy[-z]:123::OFF;
where x is the shelf number, y is the slot number, and z is the port number.
5. If a DS1 input signal is not available, bypass the Clock C source for all output
modules.
ICS command:
Type
OUTPUT BYPASS OFF
TL1 command:
SET-PRMTR-OUTPUT::SxAy[-z]:123::,,,OFF;
where x is the shelf number, y is the slot number, and z is the port number.
Repeat this command for each shelf and Output module.
6. You can manually set the output SSM for a module, overriding the SSM set by
the input:
ICS command:
Type
OUTPUT xAy PQL pql
TL1 command:
SET-OUT-PQL::SxAy:123::pql;
where x is the shelf number, y is the slot number, and pql is 0 - 16.

Saving the Provisioning Setup

After you provision each module, you can save the setup in the Communications
module memory.
ICS command:
Type
SET SAVE
TL1 command:
SET-PRMTR-SETUP::ALL:123::SAVE;
112 SSU-2000e User's Guide
, then press Enter
, then press Enter.
, then press Enter.