Removing Modules - Symmetricom SSU-2000e User Manual

Synchronization supply unit and distribution unit
Hide thumbs Also See for SSU-2000e:
Table of Contents

Advertisement

1. Connect to the SSU-2000e using one of the methods described in
Connection With the
name.
2. Log in to the system using your user name and password.
3. Disable the module using either ICS or TL1 commands:
ICS command:
Type
CONFIG 1A3 DISABLE
TL1 command:
DISC-MODULE::S1A3:123;

Removing Modules

This procedure describes how to permanently remove a module from the shelf.
Note: Modules can be removed and inserted while system power is
supplied without damaging modules or affecting system operation.
1. Connect to the SSU-2000e using one of the methods described in
Connection With the
name.
2. Log in to the system using your user name and password.
3. Disable the module using either ICS or TL1 commands. The example commands
are for slot 3 in the main shelf.
ICS command:
Type
CONFIG 1A3 DISABLE
TL1 command:
DISC-MODULE::S1A3:123;
4. Loosen the captive screws located at the top and bottom of the module front
panel.
5. Pull up on the top extractor and down on the bottom extractor to unseat the
module from the connector on the backplane.
6. Slide the module out of the shelf.
7. Install a blank filler panel to cover the empty slot.
8. Remove the module from the registry using either ICS or TL1 commands:
12713140-002-2 Revision E – October 2006
SSU-2000e, on page 90. The system prompts for a user
, then press Enter.
SSU-2000e, on page 90. The system prompts for a user
, then press Enter.
Chapter 2 Installing the SSU-2000e
Handling Modules
Establishing a
Establishing a
SSU-2000e User's Guide