Table 1-4
lists the local and remote alarm connector pin assignments.
Table 1-4. Local and Remote Alarm Connector Pin Assignments
MINOR
Normally Open Contact
MINOR
Wiper Contact
MINOR
Normally Closed Contact
MAJOR
Normally Open Contact
MAJOR
Wiper Contact
MAJOR
Normally Closed Contact
CRITICAL
CRITICAL
CRITICAL
Frame Ground
Frame Ground
Frame Ground
Not Used
Not Used
Note: In an alarm condition or loss of DC power, the contact
between the NO and COM closes and the contact between the
NC and COM opens.
Main Shelf Power Connections
The main shelf accepts redundant –48/60 VDC power inputs from external supplies
and makes these inputs available to the modules through the motherboard
connectors.
There is no power ON/OFF switch on the SSU-2000e because power to the shelf is
controlled by external power supplies.
12713140-002-2 Revision E – October 2006
Signal
Normally Open Contact
Wiper Contact
Normally Closed Contact
Chapter 1 Product Overview
Pin
7
15
8
4
12
5
1
9
2
10
11
13
3
6
SSU-2000e User's Guide
System Components
37