Installing A Module - Symmetricom SSU-2000e User Manual

Synchronization supply unit and distribution unit
Hide thumbs Also See for SSU-2000e:
Table of Contents

Advertisement

Installing a Module

The following procedure is common for all modules in the SSU-2000e and
SDU-2000e.
Note: Modules can be removed and installed while system power is
applied without damage to the modules and without affecting system
operation, unless otherwise indicated.
Install the modules by performing the following steps.
1. Align the module card edges with the plastic card guides of the selected slot.
2. Slide the module into the chassis until it seats fully into its rear panel edge
connector.
3. Tighten the captive screws located at the top and bottom of the module front
panel.
Caution: Ensure that you have completely inserted the module into
the system and that you have securely tightened the captive screws.
A partially inserted module can become easily damaged and cause
intermittent failures.
4. Enable the module using either ICS or TL1 commands. The following example
commands enable the module in slot 3 in the main shelf.
ICS command:
Type CONFIG 1A3 ENABLE, then press Enter.
TL1 command:
ACT-MODULE::S1A3:123;
Exchanging a Module
Use this procedure to exchange one type of module with the same type or a
different type of module in the same slot. The example commands are for slot 3 in
the main shelf.
1. Connect to the SSU-2000e using one of the methods described in
Connection With the
name.
2. Log in to the system using your user name and password.
3. Disable the module using either ICS or TL1 commands. The example
commands are for slot 3 in the main shelf.
12713140-002-2 Revision E – October 2006
SSU-2000e, on page 90. The system prompts for a user
Chapter 2 Installing the SSU-2000e
Handling Modules
Establishing a
SSU-2000e User's Guide
75