Factory Default (Basic) Configuration - Symmetricom SSU-2000e User Manual

Synchronization supply unit and distribution unit
Hide thumbs Also See for SSU-2000e:
Table of Contents

Advertisement

Chapter 7 Input Module Reference Data
Composite Clock Input Module

Factory Default (Basic) Configuration

The configuration settings for the Composite Clock Input module are listed in
7-12.
Table 7-12. Composite Clock Input Module Configuration Settings
Configuration Setting
Provisioned PQL
Priority
Input Signal Error Limit
Input Signal Clear Limit
Alarm Elevation Time
Port Status
Port Name
188 SSU-2000e User's Guide
Factory Default
4
0
LOS = 1, BPV = 1
LOS = 5, BPV = 5
86400 seconds
Enabled
None (blank)
Range
1 – 16
1 – 10 (0 = Monitor)
LOS: 1 – 100
BPV: 1 – 100000
LOS: 1 – 100
BPV: 1 – 100000
0 – 500000 seconds
Enabled/Disabled
Any string from 0 – 20 characters
12713140-002-2 Revision E – October 2006