Alarms are elevated from MINOR to MAJOR to CRITICAL on a per module basis
with a user-set time, from 60 to 500,000 seconds; the default is 86,400 seconds, or
one day. The elevation time is stored in each module.
You can select delay periods for software alarms from 0 to 86400 seconds. Changing
the delay period generates an event. The setting is stored in each module.
Note: If the original value is set to IMMED (–1), it means this error
delay is not allowed to change and will happen immediately.
Table 6-11
lists the Communications module alarms.
Table 6-11. Communications Module Alarms
ID
0x0
Backplane Communication Errors
0x1
Mastership Problems
0x2
Loss of Power A
0x3
Loss of Power B
0x4
SPI Watchdog Timeout
0x5
Shelf 2 Communications
0x6
Shelf 3 Communications
0x7
Shelf 4 Communications
0x8
Shelf 5 Communications
0x9
Module Removed

Configuration Data

Table 6-12
lists the factory default settings and ranges for the communication
module software configuration options.
Table 6-12. Communications Module Configuration Data
Configuration Setting
Unit Name
User List configurations
12713140-002-2 Revision E – October 2006
Description
SSU-2000e
Maximum of 25 users including four built-in users
Chapter 6 Clock Module Reference Data
Alarm
Error Delay
Level
Default
MINOR
5 sec
MINOR
5 sec
MINOR
Immediate
MINOR
Immediate
MAJOR
Immediate
CRITICAL
0 sec
CRITICAL
0 sec
CRITICAL
0 sec
CRITICAL
0 sec
MINOR
5 sec
Factory Default
SSU-2000e User's Guide 159
Communications Module
Error Delay
Settable
Yes
Yes
No
No
No
Yes
Yes
Yes
Yes
Yes