9. Provision the MTIE limits for each input port according to ITU (G.811 or G.823) or
ANSI (PRS or DS1) specifications.
ICS command:
Type
INPUT 1Ay-z MTIE PRS|DS1|G.811|G.823
where y is the slot number and z is the port number.
TL1 command:
SET-PRMTR-MTIE::S1Ay[-z]:123::{EL1|EL2|CL1|CL2},[t10],[t100],
[t1k],[t10k],[t100k];
where y is the slot number and z is the port number and alarm thresholds EL1 or
EL2 and the clear thresholds CL1 or CL2. Threshold settings t10 through t100k
are the error limits in nanoseconds for the measurement time period.
10.Assign a name, if desired, to each input port. You can assign a name of up to 20
characters.
ICS command:
Type
IONAME xAy [name]
the port number.
TL1 command:
SET-NAME::123:SxAy:name;

Provisioning Output Modules

This section describes how to enable and provision Output modules, such as DS1,
E1, or Composite Clock. You must enable and provision each output port as
appropriate. You can install Output modules in any I/O slot in the main SSU-2000e
shelf and in the SDU-2000e Expansion Shelf.
1. Log into the SSU-2000e using the procedure in
page 102.
2. Enable the modules:
ICS command:
Type
OUTPUT xAy-z ENABLE
where x is the shelf number, y is the slot number and z is the port number.
Repeat this command for each slot and port.
TL1 command:
SET-PRMTR-OUTPUT::SxA[y[-z]]:123::ON;
where x is the shelf number, y is the slot number, and z is the port number.
Repeat this command for each shelf, port, and slot.
12713140-002-2 Revision E – October 2006
Chapter 3 Provisioning and Operating the SSU-2000e
then press Enter, where x is the slot number and y is
Logging In to the
, then press Enter
Initial Provisioning
then press Enter
SSU-2000e, on