7.9 Procedure when processing Medentika-PreFace® abutment semi-finished products made of
7.9.2.3
Loading inLab MC X5 with Medentika PreFace® holders
1. Open the door of the machine by pressing the Unlock door button.
The mandrel and the workpiece holder have automatically moved
to the loading position beforehand.
2. Loosen the three screws (A) that are located on the fixing ring of the
workpiece holder using the torque wrench for the tool holder.
3. Turn the fixing ring counterclockwise and remove the fixing ring of the
workpiece holder.