Table 1-3: Power Requirement (Typical) - ADLINK Technology cPCI-6810 User Manual

Cpci-6810/6820 series 6u compactpci dual/single pentium tm iii sbc and rear i/o transition modules
Hide thumbs Also See for cPCI-6810:
Table of Contents

Advertisement

Note:
1.
2.
3.
Safety Certificate and Test
CE; FCC Class B
HALT (temperature and vibration stress) verified
All plastic material, PCB and Battery used are all UL-94V0
certified
Designed for NEBS 3.0 requirement
MTBF: >100,000 hours
Power Requirement (Typical)
Typical Current and
Maximum Current
cPCI-6810A/P9
cPCI-6810A/P9
with HDD
cPCI-6810A/1G

Table 1-3: Power Requirement (Typical)

Introduction
Certified with ADLINK thermal design. The
thermal performance is dependent on the cooling
design.
Temperature limit of optional mass storage
devices may have an impact on the thermal
specification of the board.
Operational vibration is limited by the 2.5
inch HDD. When the application requires higher
definition for anti-vibration, we recommend using
Flash2000
Flash
CompactFlash to avoid using the hard disk drive.
+5V
(+/-5%)
2.28A
3.73A
2.94A
3.73A+HDD
2.50A
3.88A
Disk
(FFD
series)
+3.3V
+12V
(+/-5%)
(+/-5%)
4.10A
3mA
14.636A
8mA
4.82A
3mA
14.636A
8mA
4.10A
3mA
14.636A
8mA
or
-12V
(+/-5%)
0mA
0mA
0mA
0mA
0mA
0mA
19