7.4
Configuring interfaces in setting mode
Important
Interfaces are set via the menus under Interfaces.
If the device is in measuring mode:
► Press shift key F1to switch to setting mode (Settings).
7.4.1

Ethernet interface (Ethernet)

Information
The Ethernet settings can only be implemented on the DMP41 (not via PC).
Choose here whether you want to use DHCP, or assign a permanent IP ad­
dress.
Permanent IP address
Enter an IP address and subnet mask suitable for your network. The gate­
way address is only used if your PC is connected via a gateway to the
DMP41(s), e.g., in order to create a connection via a different network type.
If there is any doubt, enter the same IP address as under "IP address".
DHCP
DHCP (Dynamic Host Configuration Protocol) enables automatic assign­
ment of an IP address in the network in conjunction with a server. As soon
as this automatic address link is set up, you no longer need to do anything,
an address is requested from the server and set up as soon as the DMP41
is switched on. Additional parameters (subnet mask, gateway address) can
also be specified by the network administrator and these will then also be
set.