16.4

Minimum startup configuration

Field Replaceable Units (FRU)
If the server does not start up or other problems occur, it may be necessary to
take the system down to its most basic configuration in order to isolate the
defective component.
The minimum startup configuration consists of the following components and
cables:
Component
System board
CPU with heat sink
1 memory module
Front panel module
PSU
Table 6: Minimum startup configuration - components
Cable
Front panel cable
Power cable
Table 7: Minimum startup configuration - cables