Removing The Defective 3.5-Inch Hdd Backplane; Installing The New 3.5-Inch Hdd Backplane - Fujitsu PRIMERGY RX1330 M3 Upgrade And Maintenance Manual

Hide thumbs Also See for PRIMERGY RX1330 M3:
Table of Contents

Advertisement

Hard disk drive (HDD) / solid state drive (SSD)
7.3.5.2

Removing the defective 3.5-inch HDD backplane

Ê Disconnect all cables from the HDD backplane.
I
If applicable, remove the OOB cable from the HDD backplane, too.
Ê If applicable, disconnect the ODD power and SATA cable to make room to
remove the HDD backplane easier.
Figure 93: Removing the 3.5-inch HDD backplane
Ê Pull the HDD backplane upward until the three hooks disengage (see
circles).
Ê Take out the HDD backplane.
7.3.5.3

Installing the new 3.5-inch HDD backplane

Figure 94: Installing the 3.5-inch HDD backplane
Ê Position the HDD backplane on the three hooks (see circles).
Ê Push the HDD backplane downward. Make sure that the HDD backplane fits
in the guides (A).
V
CAUTION!
Ensure that none of the cables are strained or damaged!
176