6.3

Redundant power supply

Figure 26: PSU bays
6.3.1

Installing a hot-plug PSU

Customer Replaceable Unit
(CRU)
Tools: tool-less
6.3.1.1

Preliminary steps

No steps needed.
6.3.1.2

Removing the dummy cover

Figure 27: Removing a dummy cover
Ê Press in on both release latches (1) and remove the dummy cover (2).
V
CAUTION!
Keep the dummy cover for future use. If a PSU is removed and not
immediately replaced by a new one, a dummy cover must be reinstalled
in the bay to comply with applicable EMC regulations and satisfy cooling
requirements.
RX1330 M3
PSU 1
Upgrade and Maintenance Manual
Power supply unit (PSU)
PSU 2
Hardware: 5 minutes