Installation
5.3

Mounting options

5.3.1

Terminal expansion board CUD2

CUD1
• Remove electronics board CUD1 from the electronics box by undoing the two fixing screws
• Attach the 3 hexagon-head bolts supplied at position
screws and fixing elements
The two plug connectors must be positioned such that the short pin ends are inserted in the
socket connectors of the CUD1 and the long pin ends in the socket connectors of the CUD2.
• Position board CUD2 in such a way that the two plug connectors
• Secure board CUD2 in position using the supplied screws and retaining elements
• Insert electronics board CUD1 into electronics box and tighten up the two fixing screws
as instructed.
5-24
CUD2
d
supplied and insert the two plug connectors
s
on the CUD1 electronics board with the
f
f
are properly contacted.