02.00
PNU
Description
r959
Alarm parameter 7
Parameter alarms 7 (TB alarms 1)
If one of the alarms between 97 and 112 is generated, the corresponding
segment in the display lights up.
r960
Alarm parameter 8
Parameter alarms 8 (TB alarms 2)
If one of the alarms between 113 and 128 is generated, the corresponding
segment in the display lights up.
r967
Display of control word 1
Visualization parameter for control word 1 (bits 0-15)
Identical to r650 (control word 1)
r968
Display of status word 1
Visualization parameter for status word 1 (bits 0 - 15)
Identical to r652 (status word 1)
11.46 Resetting and storing parameters,
list of existing and modified P and r parameters
P970
Restore factory setting
*
Reset parameters to factory setting (default)
0:
Parameter reset: All parameters are reset to their original
values (factory setting). This parameter is then automatically
reset to 1.
1:
No parameter reset
Note: Function can also be selected by setting P051=21.
P971
EEPROM transfer
*
Transfer of parameter values from RAM to EERPROM on switchover from
0 to 1.
It takes approximately 15s to process all values. The PMU remains in value
mode for this period.
r980
List of existing parameter numbers, start
Visualization parameter for displaying the first 100 parameter numbers in
the P or r parameter range (0 to 999). The parameter numbers are listed in
ascending sequence.
Repetition of a number over several indices means that there are no further
parameter numbers in the 0 to 999 range.
The list is continued at the parameter whose number is displayed under
index 101.
See also r989
r981
List of existing parameter numbers, continuation
See r980.
r982
List of existing parameter numbers, continuation
See r980.
r983
List of existing parameter numbers, continuation
See r980.
r984
List of existing parameter numbers, continuation
See r980.
SIEMENS AG
6RX1700-0AD76
SIMOREG DC Master
Operating Instructions
112
111
110
109
108
107
106
104
103
102
101
100 99
98
128
127
126
125
124
123
122
119
117
120
118
116 115 114 113
Value range
[Unit]
Steps
105
97
121
0 to 1
1
0 to 1
1
Parameter list
No. indices
See
Factory
Change
setting
(Access /
Type
Status)
Ind: None
P052 = 3
Type: V2
Ind: None
P052 = 3
Type: V2
Ind: None
P052 = 3
Type: V2
Ind: None
P052 = 3
Type: V2
Ind: None
P052 = 3
FS=1
P051 = 40
Type: O2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: O2
Offline
Ind: 101
P052 = 3
Type: O2
Ind: 101
P052 = 3
Type: O2
Ind: 101
P052 = 3
Type: O2
Ind: 101
P052 = 3
Type: O2
Ind: 101
P052 = 3
Type: O2
11-81