Siemens SIMOREG DC Master 6RA7028-6DS22 Operating Instructions Manual page 518

Microprocessor-based converters from 6kw to 1900kw for variable-speed dc drives 6ra70 series
Table of Contents

Advertisement

Parameter list
PNU
Description
U551
Source for multiplier for derivative-action time
(2551)
0 = Connector K0000
*
1 = Connector K0001
S00
etc.
i001:
Multiplier
i002:
Multiplier
I003:
Multiplier
i004:
Multiplier
i005:
Multiplier
i006:
Multiplier
i007:
Multiplier
i008:
Multiplier
i009:
Multiplier
i010:
Multiplier
U552
Derivative-action time
(2552)
i001:
Der.-act.time deriv./delay element 1
S00
i002:
Der.-act.time deriv./delay element 2
i003:
Der.-act.time deriv./delay element 3
i004:
Der.-act.time deriv./delay element 4
i005:
Der.-act.time deriv./delay element 5
i006:
Der.-act.time deriv./delay element 7
i008:
Der.-act.time deriv./delay element 8
i009:
Der.-act.time deriv./delay element 9
i010:
Der.-act.time deriv./delay element 10
U553
Source for multiplier for filtering time
(2553)
0 = Connector K0000
*
1 = Connector K0001
S00
etc.
i001:
Multiplier
i002:
Multiplier
i003:
Multiplier
i004:
Multiplier
i005:
Multiplier
i006:
Multiplier
i007:
Multiplier
i008:
Multiplier
i009:
Multiplier
i010:
Multiplier
U554
Filtering time
(2554)
i001:
Filtering time derivative/delay element 1
S00
i002:
Filtering time derivative/delay element 2
i003:
Filtering time derivative/delay element 3
i004:
Filtering time derivative/delay element 4
i005:
Filtering time derivative/delay element 5
i006:
Filtering time derivative/delay element 6
i007:
Filtering time derivative/delay element 7
i008:
Filtering time derivative/delay element 8
i009:
Filtering time derivative/delay element 9
i010:
Filtering time derivative/delay element 10
11.67 Setpoint reduction
U607
Source for activation of the setpoint reduction
(2607)
0 = Binector B0000
*
1 = Binector B0001
BDS
etc.
0
Setpoint reduction active
The Setpoint (before the ramp-function generator) is multiplied
by the factor set in parameter U608
1
No setpoint reduction
U608
Multiplier for speed setpoint on activation of the setpoint reduction
(2608)
FDS
11-126
derivative/delay element 1
derivative/delay element 2
derivative/delay element 3
derivative/delay element 4
derivative/delay element 5
derivative/delay element 6
derivative/delay element 7
derivative/delay element 8
derivative/delay element 9
derivative/delay element 10
derivative/delay element 1
derivative/delay element 2
derivative/delay element 3
derivative/delay element 4
derivative/delay element 5
derivative/delay element 6
derivative/delay element 7
derivative/delay element 8
derivative/delay element 9
derivative/delay element 10
Value range
[Unit]
Steps
All connector
[SW 1.8 and later]
numbers
1
(FB 270)
(FB 271)
(FB 272)
(FB 273)
(FB 274)
(FB 275)
(FB 276)
(FB 277)
(FB 278)
(FB 279)
0 to 10000
[SW 1.8 and later]
[ms]
(FB 270)
1
(FB 271)
(FB 272)
(FB 273)
(FB 274)
(FB 276)
(FB 277)
(FB 278)
(FB 279)
All connector
[SW 1.8 and later]
numbers
1
(FB 270)
(FB 271)
(FB 272)
(FB 273)
(FB 274)
(FB 275)
(FB 276)
(FB 277)
(FB 278)
(FB 279)
[SW 1.8 and later]
0 to 10000
[ms]
(FB 270)
1
(FB 271)
(FB 272)
(FB 273)
(FB 274)
(FB 275)
(FB 276)
(FB 277)
(FB 278)
(FB 279)
[SW 1.6 and later]
All binector numbers
1
0.00 to 100.00
[%]
[SW 1.6 and later]
0.01%
SIMOREG DC Master
02.00
No. indices
See
Factory
Change
setting
(Access /
Type
Status)
Ind: 10
P052 = 3
FS=1
P051 = 40
Type: L2
off-line
Ind: 10
P052 = 3
FS=100
P051 = 40
Type: O2
on-line
Ind: 10
P052 = 3
FS=1
P051 = 40
Type: L2
off-line
Ind: 10
P052 = 3
FS=100
P051 = 40
Type: O2
on-line
Ind: 2
P052 = 3
FS=9382
P051 = 40
Type: L2
off-line
Ind: 4
P052 = 3
FS=15,00
P051 = 40
Type: O2
on-line
SIEMENS AG
6RX1700-0AD76
Operating Instructions

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents