Siemens SIMOREG DC Master 6RA7028-6DS22 Operating Instructions Manual page 494

Microprocessor-based converters from 6kw to 1900kw for variable-speed dc drives 6ra70 series
Table of Contents

Advertisement

Parameter list
PNU
Description
U266
Source for control signals
(2266)
i001
Source for "Stop integrator" signal
*
(integrator is stopped when binector reaches log. "1" state)
S00
i002
Source for "Set integrator" signal
(when binector reaches log. "1" state, the integrator is set to the
value entered in parameter U267)
Settings:
0 = binector B0000
1 = binector B0001
etc.
U267
Source for setting value
(2267)
0 = connector K0000
*
1 = connector K0001
S00
etc.
Integrator 3 (output = K9222)
U268
Source for input quantity
(2268)
0 = connector K0000
*
1 = connector K0001
S00
etc.
U269
Integral-action time
(2269)
S00
U270
Source for control signals
(2270)
i001
Source for "Stop integrator" signal
*
(integrator is stopped when binector reaches log. "1" state)
S00
i002
Source for "Set integrator" signal
(when binector reaches log. "1" state, the integrator is set to the
value entered in parameter U271)
Settings:
0 = binector B0000
1 = binector B0001
etc.
U271
Source for setting value
(2271)
0 = connector K0000
*
1 = connector K0001
S00
etc.
DT1 element 1 (output = K9223, inverted: K9224)
U272
Source for input quantity
(2272)
0 = connector K0000
*
1 = connector K0001
S00
etc.
U273
Derivative-action time
(2273)
S00
U274
Filter time
(2274)
S00
DT1 element 2 (output = K9225, inverted: K9226)
U275
Source for input quantity
(2275)
0 = connector K0000
*
1 = connector K0001
S00
etc.
U276
Derivative-action time
(2276)
S00
11-102
Value range
[Unit]
Steps
All binector numbers
FB 101
1
FB 101
All connector
numbers
1
All connector
FB 102
numbers
1
FB 102 10 to 65000
[ms]
1
FB 102
All binector numbers
1
FB 102
All connector
numbers
1
All connector
FB 103
numbers
1
FB 103 0 to 1000
[ms]
1
FB 103 0 to 1000
[ms]
1
FB 104
All connector
numbers
1
FB 104 0 to 1000
[ms]
1
SIEMENS AG
SIMOREG DC Master
02.00
No. indices
See
Factory
Change
setting
(Access /
Type
Status)
Ind: 2
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=10
P051 = 40
Type: O2
Online
Ind: 2
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: O2
Online
Ind: None
P052 = 3
FS=0
P051 = 40
Type: O2
Online
Ind: None
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: O2
Online
6RX1700-0AD76
Operating Instructions

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents