Siemens SIMOREG DC Master 6RA7028-6DS22 Operating Instructions Manual page 556

Microprocessor-based converters from 6kw to 1900kw for variable-speed dc drives 6ra70 series
Table of Contents

Advertisement

Connectors and binectors
Connector
Description
Technology software S00: PI controller 4
Input quantity filtered
K9330
K9331
P component
K9332
I component
K9333
Output PI controller before limitation
K9334
Output PI controller after limitation
Positive limit for the output of the PI controller
K9335
Positive limit for the output of the PI controller (K9335) ∗ -1
K9336
K9337
Negative limit for the output of the PI controller
Technology software S00: PI controller 5
K9340
Input quantity filtered
K9341
P component
K9342
I component
Output PI controller before limitation
K9343
Output PI controller after limitation
K9344
Positive limit for the output of the PI controller
K9345
Positive limit for the output of the PI controller (K9345) ∗ -1
K9346
Negative limit for the output of the PI controller
K9347
Technology software S00: PI controller 6
Input quantity filtered
K9350
P component
K9351
I component
K9352
K9353
Output PI controller before limitation
K9354
Output PI controller after limitation
K9355
Positive limit for the output of the PI controller
Positive limit for the output of the PI controller (K9355) ∗ -1
K9356
Negative limit for the output of the PI controller
K9357
Technology software S00: PI controller 7
Input quantity filtered
K9360
K9361
P component
K9362
I component
K9363
Output PI controller before limitation
K9364
Output PI controller after limitation
Positive limit for the output of the PI controller
K9365
Positive limit for the output of the PI controller (K9365) ∗ -1
K9366
K9367
Negative limit for the output of the PI controller
Technology software S00: PI controller 8
K9370
Input quantity filtered
K9371
P component
I component
K9372
Output PI controller before limitation
K9373
Output PI controller after limitation
K9374
Positive limit for the output of the PI controller
K9375
Positive limit for the output of the PI controller (K9375) ∗ -1
K9376
12-16
[SW 1.8 and later]
[SW 1.8 and later]
[SW 1.8 and later]
[SW 1.8 and later]
[SW 1.8 and later]
Normalization
∧ 100%
=
16384
∧ 100%
=
16384
∧ 100%
=
16384
∧ 100%
=
16384
∧ 100%
=
16384
∧ 100%
=
16384
∧ 100%
=
16384
∧ 100%
=
16384
∧ 100%
=
16384
∧ 100%
=
16384
∧ 100%
=
16384
∧ 100%
=
16384
∧ 100%
=
16384
∧ 100%
=
16384
∧ 100%
=
16384
∧ 100%
=
16384
∧ 100%
=
16384
∧ 100%
=
16384
∧ 100%
=
16384
∧ 100%
=
16384
∧ 100%
=
16384
∧ 100%
=
16384
∧ 100%
=
16384
∧ 100%
=
16384
∧ 100%
=
16384
∧ 100%
=
16384
∧ 100%
=
16384
∧ 100%
=
16384
∧ 100%
=
16384
∧ 100%
=
16384
∧ 100%
=
16384
∧ 100%
=
16384
∧ 100%
=
16384
∧ 100%
=
16384
∧ 100%
=
16384
∧ 100%
=
16384
∧ 100%
=
16384
∧ 100%
=
16384
∧ 100%
=
16384
SIEMENS AG
SIMOREG DC Master
Operating Instructions
02.00
Function
diag., Sheet
FB263
B183
B183
B183
B183
B183
B183
B183
B183
FB264
B184
B184
B184
B184
B184
B184
B184
B184
FB265
B185
B185
B185
B185
B185
B185
B185
B185
FB266
B186
B186
B186
B186
B186
B186
B186
B186
FB267
B187
B187
B187
B187
B187
B187
B187
6RX1700-0AD76