Siemens SIMOREG DC Master 6RA7028-6DS22 Operating Instructions Manual page 468

Microprocessor-based converters from 6kw to 1900kw for variable-speed dc drives 6ra70 series
Table of Contents

Advertisement

Parameter list
PNU
Description
r815
Transmit data on G-SST3
When USS protocol (P800=2) is selected:
Display of data transmitted via USS interface 3
i001:
Display process data word 1
...
i016
Display process data word 16
i017:
Display parameter data word 1
...
i020:
Display parameter data word 4
When peer-to-peer (P800=5) is selected:
Display of data transmitted via peer-to-peer interface 3
i001:
Transmit data word 1
...
i005
Transmit data word 5
i006:
Not used
...
i020
Not used
Peer-to-peer interfaces: Enable transmission and receipt of telegrams:
If transmission on a peer-to-peer interface is disabled, the associated output drivers are connected to high impedance. If reception is
disabled on a peer-to-peer interface, then the telegram failure monitoring function is deactivated.
P816
Peer-to-peer 2: Source for data reception enabling command
0 = binector B0000
1 = binector B0001
etc.
P817
Peer-to-peer 2: Source for data transmission enabling command
0 = binector B0000
1 = binector B0001
etc.
P818
Peer-to-peer 3: Source for data reception enabling command
0 = binector B0000
1 = binector B0001
etc.
P819
Peer-to-peer 3: Source for data transmission enabling command
0 = binector B0000
1 = binector B0001
etc.
11.39 Deactivation of monitoring functions
WARNING
If monitoring functions are deactivated, there may be a risk to the safety of operating personnel or of
substantial property damage if a fault or error actually occurs!
P820
Deactivation of fault messages
*
The numbers of all fault messages to be deactivated must be entered in
this parameter. Fault numbers can be entered in any order. 0 must be
entered for any unused indices of the parameter.
Factory setting:
i001 = 7
i002 = 18
i003 = 31
i004 = 35
i005 = 36
i006 = 37
i007 to i099 = 0
11-76
(overvoltage)
(short circuit at binary outputs)
(monitoring of speed controller)
(drive blocked)
(armature current cannot flow)
2
(I
t motor monitoring function has responded)
Value range
No. indices
[Unit]
Factory
Steps
setting
Type
0000 to FFFF H
Ind: 20
1
Type: L2
All binector numbers
Ind: None
1
FS=1
Type: L2
All binector numbers
Ind: None
1
FS=1
Type: L2
All binector numbers
Ind: None
1
FS=1
Type: L2
All binector numbers
Ind: None
1
FS=1
Type: L2
0 to 147
Ind: 99
1
FS=
see column
on left
Type: O2
SIEMENS AG
SIMOREG DC Master
Operating Instructions
02.00
See
Change
(Access /
Status)
P052 = 3
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Online