Siemens SIMOREG DC Master 6RA7028-6DS22 Operating Instructions Manual page 484

Microprocessor-based converters from 6kw to 1900kw for variable-speed dc drives 6ra70 series
Table of Contents

Advertisement

Parameter list
PNU
Description
High-resolution multipliers/dividers
The three operands are selected via the three indices of the parameter, i.e. index i001 = x1, index i002 = x2, index i003 = x3
Equations: x
4 32
(
bit
y is limited to -200.00 to +199.99% and applied to the specified connector.
st
U155
Operands for 1
(2155)
0 = connector K0000
*
1 = connector K0001
S00
etc.
nd
U156
Operands for 2
(2156)
0 = connector K0000
*
1 = connector K0001
S00
etc.
rd
U157
Operands for 3
(2157)
0 = connector K0000
*
1 = connector K0001
S00
etc.
Absolute-value generators with filtering
U160
Source for input quantity for 1
(2160)
0 = connector K0000
*
1 = connector K0001
S00
etc.
U161
Signal injection mode for 1
(2161)
0
Injection of signal with correct sign
*
1
Injection of absolute value of signal
S00
2
Injection of signal with sign, inverted
3
Injection of absolute value of signal, inverted
U162
Filter time for 1
(2162)
S00
U163
Source for input quantity for 2
(2163)
0 = connector K0000
*
1 = connector K0001
S00
etc.
U164
Signal injection mode for 2
(2164)
0
Injection of signal with correct sign
*
1
Injection of absolute value of signal
S00
2
Injection of signal with sign, inverted
3
Injection of absolute value of signal, inverted
U165
Filter time for 2
(2165)
S00
U166
Source for input quantity for 3
(2166)
0 = connector K0000
*
1 = connector K0001
S00
etc.
U167
Signal injection mode for 3
(2167)
0
Injection of signal with correct sign
*
1
Injection of absolute value of signal
S00
2
Injection of signal with sign, inverted
3
Injection of absolute value of signal, inverted
U168
Filter time for 3
(2168)
S00
11-92
x
4
x
1
) =
=
=
x
1
x
2
, y
x
3
x
multiplier/divider (result = K9155)
multiplier/divider (result = K9156)
multiplier/divider (result = K9157)
st
abs.-value generator with filter FB 60
st
abs.-value generator with filter
st
abs.-value generator with filter
nd
abs.-value generator with filter FB 61
nd
abs.-value generator with filter
nd
abs.-value generator with filter
rd
abs.-value generator with filter FB 62
rd
abs.-value generator with filter
rd
abs.-value generator with filter
x
2
Applicable for division by 0 (x2=0):
3
When x1 > 0: y = +199.99%
When x1 = 0: y = 0.00%
When x1 < 0: y = -200.00%
FB 55
FB 56
FB 57
FB 60
FB 60 0 to 10000
FB 61
FB 61 0 to 10000
FB 62
FB 62 0 to 10000
Value range
No. indices
[Unit]
Factory
Steps
setting
Type
All connector
Ind: 3
numbers
FS=1
1
Type: L2
All connector
Ind: 3
numbers
FS=1
1
Type: L2
All connector
Ind: 3
numbers
FS=1
1
Type: L2
All connector
Ind: None
numbers
FS=0
1
Type: L2
0 to 3
Ind: None
1
FS=0
Type: O2
Ind: None
[ms]
FS=0
1
Type: O2
All connector
Ind: None
numbers
FS=0
1
Type: L2
0 to 3
Ind: None
1
FS=0
Type: O2
Ind: None
[ms]
FS=0
1
Type: O2
All connector
Ind: None
numbers
FS=0
1
Type: L2
0 to 3
Ind: None
1
FS=0
Type: O2
Ind: None
[ms]
FS=0
1
Type: O2
SIEMENS AG
SIMOREG DC Master
Operating Instructions
02.00
See
Change
(Access /
Status)
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
6RX1700-0AD76

Hide quick links: