02.00
PNU
Description
P601
Source for armature current controller setpoint
*
i001,i002 Speed limiting controller:
Selection of connectors to be injected as input quantities for
the speed limiting controller. Both values are added.
i003,i004 Current limitation:
Selection of connectors to be injected as armature current
controller setpoint (before current limitation). Both values
are added.
i005,i006 Current control:
Selection of which connectors are connected as the armature
current controller setpoint (before current controller). The
two values are added. The magnitude is formed from the
value selected with index 6.
Settings:
0 = connector K0000
1 = connector K0001
etc.
P602
Source for armature current controller actual value
*
Selection of connector to be injected as armature current controller
actual value
0 = connector K0000
1 = connector K0001
etc.
P603
Source for variable current limit in torque direction I
*
i001..i004Selection of connector to be injected as variable current limit
in torque direction I
i005
Selection of connector to be injected as current limit in torque
direction I with Fast Stop or Shutdown
Settings:
0 = connector K0000
1 = connector K0001
etc.
P604
Source for variable current limit in torque direction II
*
i001..i004Selection of connector to be injected as variable current limit
in torque direction II
i005
Selection of connector to be injected as current limit in torque
direction II with Fast Stop or Shutdown
Settings:
0
= connector K0000
...
8
= connector K0008
= value as set in parameter P603.ixx ∗ (−1)
9
10 = connector K0010
etc.
P605
Source for variable positive torque limit
*
Torque limitation:
Selection of connectors to be injected as the variable positive torque limit
(100% of connector value corresponds to positive system torque limit
obtained with settings I a =P171 and I f = P102)
0 = connector K0000
1 = connector K0001
etc.
SIEMENS AG
6RX1700-0AD76
SIMOREG DC Master
Operating Instructions
[SW 1.8 and later]
Value range
No. indices
[Unit]
Factory
Steps
setting
Type
All connector
Ind: 6
numbers
FS=
1
i001: 141
i002: 0
i003: 134
i004: 0
i005: 125
i006: 0
Type: L2
All connector
Ind: None
numbers
FS=117
1
Type: L2
All connector
Ind: 5
numbers
FS=1
1
Type: L2
All connector
Ind: 5
numbers
FS=9
1
Type: L2
All connector
Ind: 4
numbers
FS=2
1
Type: L2
Parameter list
See
Change
(Access /
Status)
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline