Siemens SIMOREG DC Master 6RA7028-6DS22 Operating Instructions Manual page 500

Microprocessor-based converters from 6kw to 1900kw for variable-speed dc drives 6ra70 series
Table of Contents

Advertisement

Parameter list
PNU
Description
U313
Source for input quantities for 3rd multiplexer
(2313)
0 = Connector K0000
*
1 = Connector K0001
S00
etc.
i001
Input quantity X0
i002
Input quantity X1
i003
Input quantity X2
i004
Input quantity X3
i005
Input quantity X4
i006
Input quantity X5
i007
Input quantity X6
i008
Input quantity X7
11.60 Logic functions
Parameters apply only if optional S00 technology software is installed
Decoders/demultiplexers, binary to 1 of 8
U318
Source for input signals for decoder/demultiplexer 1
(2318)
i001
Source for input signal, bit 0
*
i002
Source for input signal, bit 1
S00
i003
Source for input signal, bit 2
Settings:
0 = binector B0000
1 = binector B0001
etc.
U319
Source for input signals for decoder/demultiplexer 2
(2319)
i001
Source for input signal, bit 0
*
i002
Source for input signal, bit 1
S00
i003
Source for input signal, bit 2
Settings:
0 = binector B0000
1 = binector B0001
etc.
AND elements with 3 inputs each
The input signals selected via the 3 indices of the parameter are ANDed and the result of the logic operation applied to the specified
binector.
U320
Source for input signals, AND element 1 (output = B9350)
(2320)
i001
Source for input 1
*
i002
Source for input 2
S00
i003
Source for input 3
Settings:
0 = binector B0000
1 = binector B0001
etc.
U321
Source for input signals, AND element 2 (output = B9351)
(2321)
As for U320
*
S00
U322
Source for input signals, AND element 3 (output = B9352)
(2322)
As for U320
*
S00
U323
Source for input signals, AND element 4 (output = B9353)
(2323)
As for U320
*
S00
U324
Source for input signals, AND element 5 (output = B9354)
(2324)
As for U320
*
S00
11-108
Value range
[Unit]
Steps
All connector
[SW 1.8 and later]
numbers
1
FB 118
All binector numbers
1
FB 119
All binector numbers
1
All binector numbers
FB 120
1
All binector numbers
FB 121
1
FB 122
All binector numbers
1
All binector numbers
FB 123
1
FB 124
All binector numbers
1
SIMOREG DC Master
02.00
No. indices
See
Factory
Change
setting
(Access /
Type
Status)
Ind: 8
P052 = 3
FS=0
P051 = 40
Type: L2
off-line
Ind: 3
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 3
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 3
P052 = 3
FS=1
P051 = 40
Type: L2
Offline
Ind: 3
P052 = 3
FS=1
P051 = 40
Type: L2
Offline
Ind: 3
P052 = 3
FS=1
P051 = 40
Type: L2
Offline
Ind: 3
P052 = 3
FS=1
P051 = 40
Type: L2
Offline
Ind: 3
P052 = 3
FS=1
P051 = 40
Type: L2
Offline
SIEMENS AG
6RX1700-0AD76
Operating Instructions

Hide quick links:

Advertisement

Table of Contents
loading