02.00
PNU
Description
U146
Operands for 2nd divider (result = K9146)
(2146)
Operands for 5th divider (result = K9143)
*
0 = Connector K0000
S00
1 = Connector K0001
etc.
U147
Operands for 3rd divider (result = K9147)
(2147)
Operands for 6th divider (result = K9144)
*
0 = Connector K0000
S00
1 = Connector K0001
etc.
Multiplier
The two operands (x1, x2) for each multiplier are selected via 2 indices of the parameter each:
Index i001 = x1, Index i002 = x2
Index i003 = x1, Index i004 = x2 [SW 1.8 and later]
Index i005 = x1, Index i006 = x2 [SW 1.8 and later]
x
1
=
Formula: y
100%
y is limited to -200.00 to +199.99% and applied to the connector stated.
U150
Operands for 1st multiplier (result = K9150)
(2150)
Operands for 5th multiplier (result = K9430)
*
Operands for 9th multiplier (result = K9431)
S00
0 = Connector K0000
1 = Connector K0001
etc.
U151
Operands for 2nd multiplier (result = K9151)
(2151)
Operands for 6th multiplier (result = K9432)
*
Operands for 10th multiplier (result = K9433)
S00
0 = Connector K0000
1 = Connector K0001
etc.
U152
Operands for 3rd multiplier (result = K9152)
(2152)
Operands for 7thmultiplier (result = K9434)
*
Operands for 11th multiplier (result = K9435)
S00
0 = Connector K0000
1 = Connector K0001
etc.
U153
Operands for 4th multiplier (result = K9153)
(2153)
Operands for 8the multiplier (result = K9436)
*
Operands for 12th multiplier (result = K9437)
S00
0 = Connector K0000
1 = Connector K0001
etc.
SIEMENS AG
6RX1700-0AD76
SIMOREG DC Master
Operating Instructions
x
2
Value range
[Unit]
Steps
All connector
FB 46
numbers
FB 43
1
All connector
FB 47
numbers
FB 44
1
FB 50
All connector
numbers
FB 290
1
FB 291
FB 51
All connector
numbers
FB 292
1
FB 293
FB 52
All connector
numbers
FB 294
1
FB 295
FB 53
All connector
numbers
FB 296
1
FB 297
Parameter list
No. indices
See
Factory
Change
setting
(Access /
Type
Status)
Ind:
P052 = 3
2
P051 = 40
[up to
off-line
SW1.7]
4
[SW 1.8 and
later]
FS=1
Type: L2
Ind:
P052 = 3
2
P051 = 40
[up to
off-line
SW1.7]
4
[SW 1.8 and
later]
FS=1
Type: L2
Ind:
P052 = 3
2
P051 = 40
[up to
off-line
SW1.7]
6
[SW 1.8 and
later]
FS=0
Type: L2
Ind:
P052 = 3
2
P051 = 40
[up to
off-line
SW1.7]
6
[SW 1.8 and
later]
FS=0
Type: L2
Ind:
P052 = 3
2
P051 = 40
[up to
off-line
SW1.7]
6
[SW 1.8 and
later]
FS=0
Type: L2
Ind:
P052 = 3
2
P051 = 40
[up to
off-line
SW1.7]
6
[SW 1.8 and
later]
FS=0
Type: L2