Siemens SIMOREG DC Master 6RA7028-6DS22 Operating Instructions Manual page 564

Microprocessor-based converters from 6kw to 1900kw for variable-speed dc drives 6ra70 series
Table of Contents

Advertisement

Connectors and binectors
Binector
Name, description
Messages
0=AUS1 or AUS3 active, 1=no AUS1 and no AUS3 is pending
B0160
B0161
B0160 inverted
B0164
1 = n < n
min
B0165
B0164 inverted
B0166
1 = Voltage at power section is active
B0166 inverted
B0167
1 = E-Stop is active
B0168
B0168 inverted
B0169
Motor interface
1 = Monitoring brush length (Terminal 211=0) has responded, condition for A025 or F025 fulfilled
B0180
B0181
1 = Monitoring bearing state (terminal 212=1) has responded, condition for A026 or F026 fulfilled
B0182
1 = Monitoring motor fan (terminal 213=0) has responded, condition for A027 or F027 fulfilled
B0183
1 = Monitoring motor temperature (terminal 213=0) has responded, condition for A028 or F028 fulfilled
Temperature sensor inputs
B0184
1=Alarm motor temperature 1
B0185
1=Alarm motor temperature 2
Alarms
B0186
1=Alarm A037 (I2t motor) is pending
1=Alarm A039 (I2t power section) is pending
B0187
1=Alarm A067 (heat sink temperature) is pending
B0188
1=Alarm A067 (device fan) is pending
B0189
Torque limitation, current limitation, current controller, armature gating unit
Speed limitation controller: Positive speed limit reached
B0192
Speed limitation controller: Negative speed limit reached
B0193
B0194
Current limitation: Positive current limit reached
B0195
Current limitation: Negative current limit reached
α
B0196
limit reached
G
α
B0197
limit reached
W
B0200
Current limitation active
Speed limiting controller active
B0201
Upper torque limitation active
B0202
Lower torque limitation active
B0203
Torque or current limitation active or current controller at limitation
B0204
Speed controller
B0205
Speed controller enabling by sequencing control
Setpoint processing, ramp-function generator
B0206
Limitation after ramp-function generator (setpoint limitation) has responded
B0207
Ramp-function generator output = 0 (y = 0)
B0208
Ramp-function generator, ramp-up
B0209
Ramp-function generator, ramp-down
B0210
1 = no direction of rotation enabled
Ramp-function generator: Enable setpoint (1 = setpoint enabled)
B0211
12-24
[SW 1.4 and later]
[SW 1.4 and later]
[SW 1.4 and later]
[SW 1.4 and later]
[SW 1.4 and later]
[SW 1.4 and later]
[SW 1.6 and later]
[SW 1.6 and later]
[SW 1.8 and later]
[SW 1.8 and later]
[SW 1.8 and later]
[SW 1.8 and later]
[SW 1.8 and later]
[SW 1.8 and later]
[SW 1.6 and later]
SIEMENS AG
SIMOREG DC Master
Operating Instructions
02.00
Function
diag., Sheet
G180
G180
G212
G212
G186
G186
G186
G186
G185
G185
G160
G160
G161
G161
G162
G162
G161
G160
G160
G160
G162
G152
G136
G136
G136
G136
G135
G136
6RX1700-0AD76