Siemens SIMOREG DC Master 6RA7028-6DS22 Operating Instructions Manual page 503

Microprocessor-based converters from 6kw to 1900kw for variable-speed dc drives 6ra70 series
Table of Contents

Advertisement

02.00
PNU
Description
U360
Source for input signals, OR element 11 (output = B9390)
(2360)
As for U350
*
S00
U361
Source for input signals, OR element 12 (output = B9391)
(2361)
As for U350
*
S00
U362
Source for input signals, OR element 13 (output = B9392)
(2362)
As for U350
*
S00
U363
Source for input signals, OR element 14 (output = B9393)
(2363)
As for U350
*
S00
U364
Source for input signals, OR element 15 (output = B9394)
(2364)
As for U350
*
S00
U365
Source for input signals, OR element 16 (output = B9395)
(2365)
As for U350
*
S00
U366
Source for input signals, OR element 17 (output = B9396)
(2366)
As for U350
*
S00
U367
Source for input signals, OR element 18 (output = B9397)
(2367)
As for U350
*
S00
U368
Source for input signals, OR element 19 (output = B9398)
(2368)
As for U350
*
S00
U369
Source for input signals, OR element 20 (output = B9399)
(2369)
As for U350
*
S00
EXCLUSIVE OR elements with 2 inputs each
The input signals selected via the 2 indices of the parameter are combined in an EXCLUSIVE OR (XOR) operation and the result applied
to the specified binector.
U370
Source for input signals, XOR element 1 (output = B9195)
(2370)
i001
Source for input 1
*
i002
Source for input 2
S00
Settings:
0 = binector B0000
1 = binector B0001
etc.
U371
Source for input signals, XOR element 2 (output = B9196)
(2371)
As for U370
*
S00
U372
Source for input signals, XOR element 3 (output = B9197)
(2372)
As for U370
*
S00
U373
Source for input signals, XOR element 4 (output = B9198)
(2373)
As for U370
*
S00
SIEMENS AG
6RX1700-0AD76
SIMOREG DC Master
Operating Instructions
Value range
[Unit]
Steps
All binector numbers
FB 160
1
FB 161
All binector numbers
1
All binector numbers
FB 162
1
FB 163
All binector numbers
1
All binector numbers
FB 164
1
FB 165
All binector numbers
1
All binector numbers
FB 166
1
FB 167
All binector numbers
1
All binector numbers
FB 168
1
FB 169
All binector numbers
1
All binector numbers
FB 170
1
All binector numbers
FB 171
1
FB 172
All binector numbers
1
FB 173
All binector numbers
1
Parameter list
No. indices
See
Factory
Change
setting
(Access /
Type
Status)
Ind: 3
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 3
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 3
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 3
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 3
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 3
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 3
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 3
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 3
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 3
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 2
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 2
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 2
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 2
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
11-111